A Low-Cost Handheld Centrifugal Microfluidic System for Multiplexed Visual Detection Based on Isothermal Amplification
Sensors · 2024
DOI: 10.3390/s24155028 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Nan Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Microfluidic Chip Development in Biomedical Engineering, College of Information Science and Technology, Beijing University of Chemical T…. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Research fund to the top scientific and technological innovation team from Beijing University of Chemical Technology, China.
Abstract (Originalsprache)
A low-cost, handheld centrifugal microfluidic system for multiplexed visual detection based on recombinase polymerase amplification (RPA) was developed. A concise centrifugal microfluidic chip featuring four reaction units was developed to run multiplexed RPA amplification in parallel. Additionally, a significantly shrunk-size and cost-effective handheld companion device was developed, incorporating heating, optical, rotation, and sensing modules, to perform multiplexed amplification and visual detection. After one-time sample loading, the metered sample was equally distributed into four separate reactors with high-speed centrifugation. Non-contact heating was adopted for isothermal amplification. A tiny DC motor on top of the chip was used to drive steel beads inside reactors for active mixing. Another small DC motor, which was controlled by an elaborate locking strategy based on magnetic sensing, was adopted for centrifugation and positioning. Visual fluorescence detection was optimized from different sides, including material, surface properties, excitation light, and optical filters. With fluorescence intensity-based visual detection, the detection results could be directly observed through the eyes or with a smartphone. As a proof of concept, the handheld device could detect multiple targets, e.g., different genes of African swine fever virus (ASFV) with the comparable LOD (limit of detection) of 75 copies/test compared to the tube-based RPA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Microfluidic Chip Development in Biomedical Engineering, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China.
ORCID-Profile: Lulu Zhang, Xianbo Qiu
Förderung
- National Natural Science Foundation of China
- Research fund to the top scientific and technological innovation team from Beijing University of Chemical Technology, China
Zitieren
APA
Wang, N., Dong, X., Zhou, Y., Zhu, R., Liu, L., Zhang, L., & Qiu, X. (2024). A Low-Cost Handheld Centrifugal Microfluidic System for Multiplexed Visual Detection Based on Isothermal Amplification. Sensors. https://doi.org/10.3390/s24155028
Vancouver
Wang N, Dong X, Zhou Y, Zhu R, Liu L, Zhang L, et al. A Low-Cost Handheld Centrifugal Microfluidic System for Multiplexed Visual Detection Based on Isothermal Amplification. Sensors. 2024. doi:10.3390/s24155028
BibTeX
@article{Wang2024,
author = {Wang, Nan and Dong, Xiaobin and Zhou, Yijie and Zhu, Rui and Liu, Luyao and Zhang, Lulu and Qiu, Xianbo},
title = {A Low-Cost Handheld Centrifugal Microfluidic System for Multiplexed Visual Detection Based on Isothermal Amplification},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24155028}
}