EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Smartphone-driven centrifugal microfluidics for diagnostics in resource limited settings

Noa Lapins, Ahmad S Akhtar, Indradumna Banerjee, Amin Kazemzadeh, Inês F Pinto, Aman Russom

Biomedical Microdevices · 2024-12 · 26 (4)

DOI: 10.1007/s10544-024-00726-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Microdevices, online erschienen am 26.10.2024. Verfasst von Noa Lapins und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, KTH Royal Institute of Technology, Solna, Sweden. Hauptthemen laut MEDLINE: Smartphone, Centrifugation. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Royal Institute of Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The broad availability of smartphones has provided new opportunities to develop less expensive, portable, and integrated point-of-care (POC) platforms. Here, a platform that consists of three main components is introduced: a portable housing, a centrifugal microfluidic disc, and a mobile phone. The mobile phone supplies the electrical power and serves as an analysing system. The low-cost housing made from cardboard serves as a platform to conduct tests. The electrical energy stored in mobile phones was demonstrated to be adequate for spinning a centrifugal disc up to 3000 revolutions per minute (RPM), a rotation speed suitable for majority of centrifugal microfluidics-based assays. For controlling the rotational speed, a combination of magnetic and acoustic tachometry using embedded sensors of the mobile phone was used. Experimentally, the smartphone-based tachometry was proven to be comparable with a standard laser-based tachometer. As a proof of concept, two applications were demonstrated using the portable platform: a colorimetric sandwich immunoassay to detect interleukin-2 (IL-2) having a limit of detection (LOD) of 65.17 ng/mL and a fully automated measurement of hematocrit level integrating blood-plasma separation, imaging, and image analysis that takes less than 5 mins to complete. The low-cost platform weighing less than 150 g and operated by a mobile phone has the potential to meet the REASSURED criteria for advanced diagnostics in resource limited settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphoneCentrifugationHumansLab-On-A-Chip DevicesEquipment DesignPoint-of-Care SystemsLimit of DetectionImmunoassayResource-Limited Settings

Stichwörter der Autor:innen

Centrifugal microfluidicsColorimetryPoint-of-care diagnosticsResource limited settings

Autor:innen und Institutionen

  • Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, KTH Royal Institute of Technology, Solna, Sweden.
  • Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, KTH Royal Institute of Technology, Solna, Sweden. aman@kth.se.
  • AIMES - Center for the Advancement of Integrated Medical and Engineering Sciences at Karolinska Institutet and KTH Royal Institute of Technology, Stockholm, Sweden. aman@kth.se.

Förderung

  • Royal Institute of Technology

Zitieren

APA

Lapins, N., Akhtar, A. S., Banerjee, I., Kazemzadeh, A., Pinto, I. F., & Russom, A. (2024). Smartphone-driven centrifugal microfluidics for diagnostics in resource limited settings. Biomedical Microdevices, 26(4). https://doi.org/10.1007/s10544-024-00726-x

Vancouver

Lapins N, Akhtar AS, Banerjee I, Kazemzadeh A, Pinto IF, Russom A. Smartphone-driven centrifugal microfluidics for diagnostics in resource limited settings. Biomedical Microdevices. 2024;26(4). doi:10.1007/s10544-024-00726-x

BibTeX
@article{Lapins2024,
  author = {Lapins, Noa and Akhtar, Ahmad S and Banerjee, Indradumna and Kazemzadeh, Amin and Pinto, Inês F and Russom, Aman},
  title = {Smartphone-driven centrifugal microfluidics for diagnostics in resource limited settings},
  journal = {Biomedical Microdevices},
  year = {2024},
  volume = {26},
  number = {4},
  doi = {10.1007/s10544-024-00726-x}
}
Kostenlos starten →