EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accelerometer Thresholds for Estimating Physical Activity Intensity Levels in Infants: A Preliminary Study

Mustafa A Ghazi iD, Judy Zhou, Kathryn L Havens, Beth A Smith

Sensors · 09.07.2024 · 24 (14) · 4436

DOI: 10.3390/s24144436 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 09.07.2024. Verfasst von Mustafa A Ghazi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Developmental-Behavioral Pediatrics, Children's Hospital Los Angeles, Los Angeles, CA 90027, USA. Hauptthemen laut MEDLINE: Accelerometry, Exercise. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CAL-PT FUND, American Physical Therapy Association Academy of Pediatric Physical Therapy.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lack of physical activity (PA) at a young age can result in health issues. Thus, monitoring PA is important. Wearable accelerometers are the preferred tool to monitor PA in children. Validated thresholds are used to classify activity intensity levels, e.g., sedentary, light, and moderate-to-vigorous, in ambulatory children. No previous work has developed accelerometer thresholds for infancy (pre-ambulatory children). Therefore, this work aims to develop accelerometer thresholds for PA intensity levels in pre-ambulatory infants. Infants (n = 10) were placed in a supine position and allowed free movement. Their movements were synchronously captured using video cameras and accelerometers worn on each ankle. The video data were labeled by activity intensity level (sedentary, light, and moderate-to-vigorous) in two-second epochs using observational rating (gold standard). Accelerometer thresholds were developed for acceleration and jerk using two optimization approaches. Four sets of thresholds were developed for dual (two ankles) and for single-worn (one ankle) accelerometers. Of these, for a typical use case, we recommend using acceleration-based thresholds of 1.00 m/s to distinguish sedentary and light activity and 2.60 m/s to distinguish light and moderate-to-vigorous activity. Acceleration and jerk are both suitable for measuring PA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AccelerometryExerciseHumansInfantMaleFemaleWearable Electronic Devices

Stichwörter der Autor:innen

infantphysical activity intensitythresholdvalidationwearable accelerometer

Autor:innen und Institutionen

  • Division of Developmental-Behavioral Pediatrics, Children's Hospital Los Angeles, Los Angeles, CA 90027, USA.
  • Division of Biokinesiology and Physical Therapy, Ostrow School of Dentistry, University of Southern California, Los Angeles, CA 90089, USA.
  • Developmental Neuroscience and Neurogenetics Program, The Saban Research Institute, Children's Hospital Los Angeles, Los Angeles, CA 90027, USA.
  • Department of Pediatrics, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, USA.

ORCID-Profile: Mustafa A Ghazi

Förderung

  • CAL-PT FUND
  • American Physical Therapy Association Academy of Pediatric Physical Therapy

Zitieren

APA

Ghazi, M. A., Zhou, J., Havens, K. L., & Smith, B. A. (2024). Accelerometer Thresholds for Estimating Physical Activity Intensity Levels in Infants: A Preliminary Study. Sensors, 24(14), 4436. https://doi.org/10.3390/s24144436

Vancouver

Ghazi MA, Zhou J, Havens KL, Smith BA. Accelerometer Thresholds for Estimating Physical Activity Intensity Levels in Infants: A Preliminary Study. Sensors. 2024;24(14):4436. doi:10.3390/s24144436

BibTeX
@article{Ghazi2024,
  author = {Ghazi, Mustafa A and Zhou, Judy and Havens, Kathryn L and Smith, Beth A},
  title = {Accelerometer Thresholds for Estimating Physical Activity Intensity Levels in Infants: A Preliminary Study},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {14},
  pages = {4436},
  doi = {10.3390/s24144436}
}
Kostenlos starten →