Oxygen Saturation Curve Analysis in 2298 Hypoxia Awareness Training Tests of Military Aircrew Members in a Hypobaric Chamber

Manuel Alvear-Catalán, Claudio Montiglio, Danilo Aravena-Nazif, Ginés Viscor iD, Oscar F Araneda iD

Sensors · 2024

DOI: 10.3390/s24134168 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Manuel Alvear-Catalán und 4 weiteren Autor:innen. Beteiligte Einrichtung: Centro de Medicina Aeroespacial (CMAE), Fuerza Aérea de Chile, Santiago 7550000, Chile. Hauptthemen laut MEDLINE: Military Personnel, Hypoxia, Oxygen Saturation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We aim to provide reference values for military aircrews participating in hypoxia awareness training (HAT). We describe several parameters with potential biomedical interest based on selected segments and slopes of the changes in oxygen saturation (SatO2) during a standard HAT. A retrospective analysis of 2298 records of the SatO2 curve was performed, including 1526 military men aged 30.48 ± 6.47 years during HAT in a hypobaric chamber. HAT consisted of pre-oxygenation at 100% and an ascent to 7620 m, followed by O2 disconnection starting the phase of descent of SatO2 until reaching the time of useful consciousness (TUC), and finally reconnection to 100% O2 in the recovery phase. Using an ad hoc computational procedure, the time taken to reach several defined critical values was computed. These key parameters were the time until desaturation of 97% and 90% (hypoxia) after oxygen mask disconnection (D97/D90) and reconnection (R97/R90) phases, the time of desaturation (TUC-D97) and hypoxia (TUC-D90) during disconnection, the total time in desaturation (L97) or hypoxia (L90), and the slopes of SatO2 drop (SDSAT97 and SDSAT90) and recovery (SRSAT97). The mean of the quartiles according to TUC were compared by ANOVA. The correlations between the different parameters were studied using Pearson’s test and the effect size was estimated with ω2. Potentially useful parameters for the HAT study were those with statistical significance (p < 0.05) and a large effect size. D97, D90, R97, and R90 showed significant differences with small effect sizes, while TUC-D97, TUC-D90, L97, L90, and SDSAT97 showed significant differences and large effect sizes. SDSAT97 correlated with TUC (R = 0.79), TUC-D97 (R = 0.81), and TUC-D90 (R = 0.81). In conclusion, several parameters of the SatO2 curve are useful for the study and monitoring of HAT. The SDSAT97 measured during the test can estimate the TUC and thus contribute to taking measures to characterize and protect the aircrew members.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Military PersonnelHypoxiaOxygen SaturationHumansMaleAdultRetrospective StudiesOxygenAltitude

Stichwörter der Autor:innen

acute hypobaric hypoxiaaircrewshypoxia awareness trainingperipheral oxygen saturationslope of arterial oxygen saturation curve

Substanzen

Oxygen

Autor:innen und Institutionen

  • Centro de Medicina Aeroespacial (CMAE), Fuerza Aérea de Chile, Santiago 7550000, Chile.
  • Secció de Fisiologia, Departament de Biologia Cel·lular, Fisiologia i Immunologia, Facultat de Biologia, Universitat de Barcelona, 08028 Barcelona, Spain.
  • Facultad de Medicina, Clínica Alemana Universidad del Desarrollo, Santiago 7610315, Chile.
  • Integrative Laboratory of Biomechanics and Physiology of Effort, (LIBFE), School of Kinesiology, Faculty of Medicine, Universidad de los Andes, Santiago 7620001, Chile.

ORCID-Profile: Ginés Viscor, Oscar F Araneda

Zitieren

APA

Alvear-Catalán, M., Montiglio, C., Aravena-Nazif, D., Viscor, G., & Araneda, O. F. (2024). Oxygen Saturation Curve Analysis in 2298 Hypoxia Awareness Training Tests of Military Aircrew Members in a Hypobaric Chamber. Sensors. https://doi.org/10.3390/s24134168

Vancouver

Alvear-Catalán M, Montiglio C, Aravena-Nazif D, Viscor G, Araneda OF. Oxygen Saturation Curve Analysis in 2298 Hypoxia Awareness Training Tests of Military Aircrew Members in a Hypobaric Chamber. Sensors. 2024. doi:10.3390/s24134168

BibTeX
@article{AlvearCataln2024,
  author = {Alvear-Catalán, Manuel and Montiglio, Claudio and Aravena-Nazif, Danilo and Viscor, Ginés and Araneda, Oscar F},
  title = {Oxygen Saturation Curve Analysis in 2298 Hypoxia Awareness Training Tests of Military Aircrew Members in a Hypobaric Chamber},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24134168}
}
Kostenlos starten →