EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Performance of pulse oximeters as a function of race compared to skin pigmentation: a single center retrospective study

Audrey I Marlar, Bradley K Knabe, Yasamin Taghikhan, Richard L Applegate, Neal W Fleming iD

Journal of Clinical Monitoring and Computing · 2024

DOI: 10.1007/s10877-024-01211-9 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Clinical Monitoring and Computing, 2024. Verfasst von Audrey I Marlar und 4 weiteren Autor:innen. Beteiligte Einrichtung: Davis School of Medicine, University of California, Sacramento, CA, USA. Hauptthemen laut MEDLINE: Skin Pigmentation, Oximetry, Racial Groups. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pulse oximetry (SpO 2 ) is a critical monitor for assessing oxygenation status and guiding therapy in critically ill patients. Race has been identified as a potential source of SpO 2 error, with consequent bias and inequities in healthcare. This study was designed to evaluate the incidence of occult hypoxemia and accuracy of pulse oximetry associated with the Massey-Martin scale and characterize the relationship between Massey scores and self-identified race. This retrospective single institute study utilized the Massey-Martin scale as a quantitative assessment of skin pigmentation. These values were recorded peri-operatively in patients enrolled in unrelated clinical trials. The electronic medical record was utilized to obtain demographics, arterial blood gas values, and time matched SpO 2 values for each PaO 2 ≤ 125 mmHg recorded throughout their hospitalizations. Differences between SaO 2 and SpO 2 were compared as a function of both Massey score and self-reported race. 4030 paired SaO 2 -SpO 2 values were available from 579 patients. The average error (SaO 2 -SpO 2 ) ± SD was 0.23 ± 2.6%. Statistically significant differences were observed within Massey scores and among races, with average errors that ranged from − 0.39 ± 2.3 to 0.53 ± 2.5 and − 0.55 ± 2.1 to 0.37 ± 2.7, respectively. Skin color varied widely within each self-identified race category. There was no clinically significant association between error rates and Massey-Martin scale grades and no clinically significant difference in accuracy observed between self-reported Black and White patients. In addition, self-reported race is not an appropriate surrogate for skin color.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Skin PigmentationOximetryRacial GroupsHumansRetrospective StudiesMaleFemaleMiddle AgedAgedOxygen SaturationHypoxiaAdultOxygenBlood Gas AnalysisReproducibility of ResultsMonitoring, Physiologic

Stichwörter der Autor:innen

Massey-Martin scaleOxygenationPulse oximetersRaceRacial biasSkin pigmentation

Substanzen

Oxygen

Autor:innen und Institutionen

  • Davis School of Medicine, University of California, Sacramento, CA, USA.
  • Department of Anesthesiology, Loma Linda University, Loma Linda, CA, USA.
  • Department of Anesthesiology & Pain Medicine, Davis School of Medicine, University of California, Sacramento, CA, USA. nwfleming@ucdavis.edu.
  • Department of Anesthesiology & Pain Medicine, UC Davis Medical Center, 4150 V Street PSSB - Suite1200, Sacramento, CA, 95817-1460, USA. nwfleming@ucdavis.edu.

ORCID-Profile: Neal W Fleming

Zitieren

APA

Marlar, A. I., Knabe, B. K., Taghikhan, Y., Applegate, R. L., & Fleming, N. W. (2024). Performance of pulse oximeters as a function of race compared to skin pigmentation: a single center retrospective study. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-024-01211-9

Vancouver

Marlar AI, Knabe BK, Taghikhan Y, Applegate RL, Fleming NW. Performance of pulse oximeters as a function of race compared to skin pigmentation: a single center retrospective study. Journal of Clinical Monitoring and Computing. 2024. doi:10.1007/s10877-024-01211-9

BibTeX
@article{Marlar2024,
  author = {Marlar, Audrey I and Knabe, Bradley K and Taghikhan, Yasamin and Applegate, Richard L and Fleming, Neal W},
  title = {Performance of pulse oximeters as a function of race compared to skin pigmentation: a single center retrospective study},
  journal = {Journal of Clinical Monitoring and Computing},
  year = {2024},
  doi = {10.1007/s10877-024-01211-9}
}
Kostenlos starten →