Polycations as Aptamer-Binding Modulators for Sensitive Fluorescence Anisotropy Assay of Aflatoxin B1
Sensors · 2024
DOI: 10.3390/s24103230 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Alexey V Samokhvalov und 4 weiteren Autor:innen. Beteiligte Einrichtung: A.N. Bach Institute of Biochemistry, Research Center of Biotechnology, Russian Academy of Sciences, 119071 Moscow, Russia. Hauptthemen laut MEDLINE: Aflatoxin B1, Aptamers, Nucleotide, Fluorescence Polarization. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Russian Science Foundation.
Abstract (Originalsprache)
Fluorescence induced by the excitation of a fluorophore with plane-polarized light has a different polarization depending on the size of the fluorophore-containing reagent and the rate of its rotation. Based on this effect, many analytical systems have been implemented in which an analyte contained in a sample and labeled with a fluorophore (usually fluorescein) competes to bind to antibodies. Replacing antibodies in such assays with aptamers, low-cost and stable oligonucleotide receptors, is complicated because binding a fluorophore to them causes a less significant change in the polarization of emissions. This work proposes and characterizes the compounds of the reaction medium that improve analyte binding and reduce the mobility of the aptamer–fluorophore complex, providing a higher analytical signal and a lower detection limit. This study was conducted on aflatoxin B1 (AFB1), a ubiquitous toxicant contaminating foods of plant origins. Eight aptamers specific to AFB1 with the same binding site and different regions stabilizing their structures were compared for affinity, based on which the aptamer with 38 nucleotides in length was selected. The polymers that interact reversibly with oligonucleotides, such as poly-L-lysine and polyethylene glycol, were tested. It was found that they provide the desired reduction in the depolarization of emitted light as well as high concentrations of magnesium cations. In the selected optimal medium, AFB1 detection reached a limit of 1 ng/mL, which was 12 times lower than in the tris buffer commonly used for anti-AFB1 aptamers. The assay time was 30 min. This method is suitable for controlling almond samples according to the maximum permissible levels of their contamination by AFB1. The proposed approach could be applied to improve other aptamer-based analytical systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology, Russian Academy of Sciences, 119071 Moscow, Russia.
- Faculty of Chemistry, M.V. Lomonosov Moscow State University, 119991 Moscow, Russia.
ORCID-Profile: Anatoly V Zherdev, Boris B Dzantiev
Förderung
- Russian Science Foundation
Zitieren
APA
Samokhvalov, A. V., Mironova, A. A., Eremin, S. A., Zherdev, A. V., & Dzantiev, B. B. (2024). Polycations as Aptamer-Binding Modulators for Sensitive Fluorescence Anisotropy Assay of Aflatoxin B1. Sensors. https://doi.org/10.3390/s24103230
Vancouver
Samokhvalov AV, Mironova AA, Eremin SA, Zherdev AV, Dzantiev BB. Polycations as Aptamer-Binding Modulators for Sensitive Fluorescence Anisotropy Assay of Aflatoxin B1. Sensors. 2024. doi:10.3390/s24103230
BibTeX
@article{Samokhvalov2024,
author = {Samokhvalov, Alexey V and Mironova, Alena A and Eremin, Sergei A and Zherdev, Anatoly V and Dzantiev, Boris B},
title = {Polycations as Aptamer-Binding Modulators for Sensitive Fluorescence Anisotropy Assay of Aflatoxin B1},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24103230}
}
EUVIMED