EUVIMEDEUVIMED entdecken
Crossref

A ratiometric fluorescent aptamer assay based on RCA amplification mult-G-quadruplex

Xinyu Xie, Weiling Li, Zhiguang Suo, Rui Guo, Min Wei, Huali Jin

Analytical and Bioanalytical Chemistry · 2025

DOI: 10.1007/s00216-025-06083-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2025. Verfasst von Xinyu Xie und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety and Nutrition, Henan University of Technology, Zhengzhou, …. Hauptthemen laut MEDLINE: G-Quadruplexes, Aptamers, Nucleotide, Fluorescent Dyes, Aflatoxin B1. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 37 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ratiometric assay with dual signals can effectively avoid false positives of single signals. Therefore, a dual-signal assay was designed to detect Aflatoxin B1 (AFB1) using the affinity of the aptamers to the target as well as the binding force between the DNA strands. The first fluorescent signal was obtained by binding AFB1 to aptamer to shed the complementary sequence with the FAM (6-carboxyfluorescein). The G-quadruplex is a common DNA conformation capable of emitting light with special fluorescent dyes. At room temperature, the G-quadruplex is opened by the shed complementary strand to form double-stranded DNA, disrupting its original structure. The NMM (N-methylmesoporphyrin IX) dye is unable to embed the G-quadruplex and emit light. Taking advantage of the DNA conformational transition, NMM dye was introduced as the second fluorescence signal. Based on the above principle, a dual fluorescence signal ratiometric assay was constructed for the detection of AFB1 by the ratio of FAM and NMM fluorescence intensity. This study provides a prospective strategy for developing a dual-signal construct ratio assay.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

G-QuadruplexesAptamers, NucleotideFluorescent DyesAflatoxin B1Biosensing TechniquesNucleic Acid Amplification TechniquesSpectrometry, FluorescenceLimit of DetectionMesoporphyrins

Stichwörter der Autor:innen

Aflatoxin B1Mult-G-quadruplex nanostructureRCARatiometric fluorescent assay

Substanzen

Aptamers, NucleotideFluorescent DyesAflatoxin B1MesoporphyrinsN-methylmesoporphyrin IX

Autor:innen und Institutionen

  • College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety and Nutrition, Henan University of Technology, Zhengzhou, 450001, China.
  • College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety and Nutrition, Henan University of Technology, Zhengzhou, 450001, China. zg_suo@163.com.
  • Henan Institute of Product Quality Inspection Technology, Zhengzhou, 450047, China.

Zitieren

APA

Xie, X., Li, W., Suo, Z., Guo, R., Wei, M., & Jin, H. (2025). A ratiometric fluorescent aptamer assay based on RCA amplification mult-G-quadruplex. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-025-06083-9

Vancouver

Xie X, Li W, Suo Z, Guo R, Wei M, Jin H. A ratiometric fluorescent aptamer assay based on RCA amplification mult-G-quadruplex. Analytical and Bioanalytical Chemistry. 2025. doi:10.1007/s00216-025-06083-9

BibTeX
@article{Xie2025,
  author = {Xie, Xinyu and Li, Weiling and Suo, Zhiguang and Guo, Rui and Wei, Min and Jin, Huali},
  title = {A ratiometric fluorescent aptamer assay based on RCA amplification mult-G-quadruplex},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2025},
  doi = {10.1007/s00216-025-06083-9}
}
Kostenlos starten →