On the Influence of Humidity on a Thermal Conductivity Sensor for the Detection of Hydrogen
Sensors · 24.04.2024 · 24 (9) · 2697
DOI: 10.3390/s24092697 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 24.04.2024. Verfasst von Sophie Emperhoff und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Microsystems Engineering (IMTEK), Albert-Ludwigs-Universität Freiburg, 79110 Freiburg im Breisgau, Germany. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry for Economic Affairs and Climate Action, German Federal Ministry of Economic Affairs and Climate Action (BMWK).
Abstract (Originalsprache)
Thermal conductivity sensors face an omnipresent cross-influence through varying humidity levels in real-life applications. We present the results of investigations on the influence of humidity on a hydrogen thermal conductivity sensor and approaches for predicting the behavior of thermal conductivity towards humidity. A literature search and comparison of different mixing equations for binary gas mixtures were carried out. The theoretical results were compared with experimental results from three different thermal conductivity sensors with mixtures of water vapor in nitrogen. The mixing equations show a large discrepancy between each other. Some of the models predict a continuously decreasing thermal conductivity and some predict an increasing thermal conductivity for increasing levels of humidity. Our measurements indicate an increase in thermal conductivity followed by a decrease after reaching a peak value. It is shown that the measured behavior is reproducible with different sensors. Depending on the sensor, this corresponds to an error up to 2 vol.% in the measured hydrogen value. The measured behavior is consistent with only one of the three models. Compared to this model, our own sensor shows a maximum deviation of 1.4%. Mixing equations for gas mixtures must be chosen carefully, taking into consideration whether mixing partners include polar or non-polar molecules. Some simplified mixing equations cannot be used to calculate the thermal conductivity of water vapor in air or nitrogen.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Microsystems Engineering (IMTEK), Albert-Ludwigs-Universität Freiburg, 79110 Freiburg im Breisgau, Germany.
- Infineon Technologies AG, 81549 Neubiberg, Germany.
- Fraunhofer Institute for Physical Measurement Techniques (IPM), 79110 Freiburg, Germany.
Förderung
- Federal Ministry for Economic Affairs and Climate Action
- German Federal Ministry of Economic Affairs and Climate Action (BMWK)
Zitieren
APA
Emperhoff, S., Eberl, M., Dwertmann, T., & Wöllenstein, J. (2024). On the Influence of Humidity on a Thermal Conductivity Sensor for the Detection of Hydrogen. Sensors, 24(9), 2697. https://doi.org/10.3390/s24092697
Vancouver
Emperhoff S, Eberl M, Dwertmann T, Wöllenstein J. On the Influence of Humidity on a Thermal Conductivity Sensor for the Detection of Hydrogen. Sensors. 2024;24(9):2697. doi:10.3390/s24092697
BibTeX
@article{Emperhoff2024,
author = {Emperhoff, Sophie and Eberl, Matthias and Dwertmann, Tim and Wöllenstein, Jürgen},
title = {On the Influence of Humidity on a Thermal Conductivity Sensor for the Detection of Hydrogen},
journal = {Sensors},
year = {2024},
volume = {24},
number = {9},
pages = {2697},
doi = {10.3390/s24092697}
}
EUVIMED