EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simultaneous Electrochemical Detection of Cu2+ and Zn2+ in Pig Farm Wastewater

Jia-Xin Du, Yang-Hao Ma, Said Nawab, Yang-Chun Yong iD

Sensors · 2024

DOI: 10.3390/s24082475 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Jia-Xin Du und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biofuels Institute and Institute for Energy Research, School of Environment and Safety Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang 212…. Hauptthemen laut MEDLINE: Wastewater, Copper, Zinc, Electrochemical Techniques. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In recent years, the rapid development of pig farming has led to a large quantity of heavy metal-polluted wastewater. Thus, it was desirable to develop a simple heavy metal detection method for fast monitoring of the wastewater from the pig farms. Therefore, there was an urgent need to develop a simple method for rapidly detecting heavy metal ions in pig farm wastewater. Herein, a simple electrochemical method for simultaneous detection of Cu2+ and Zn2+ was developed and applied to pig farm wastewater. With a glassy carbon electrode and anodic stripping voltammetry, simultaneous detection of Cu2+ and Zn2+ in water was achieved without the need for complicated electrode modification. Furthermore, it was found that the addition of Cd2+ can enhance the response current of the electrode to Zn2+, which increased the signal by eight times. After systematic optimization, the limit of detection (LOD) of 9.3 μg/L for Cu2+ and 45.3 μg/L for Zn2+ was obtained. Finally, it was successfully applied for the quantification of Cu2+ and Zn2+ with high accuracy in pig farm wastewater. This work provided a new and simple solution for fast monitoring of the wastewater from pig farms and demonstrated the potential of electrochemical measurement for application in modern animal husbandry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WastewaterCopperZincElectrochemical TechniquesFarmsAnimalsSwineWater Pollutants, ChemicalElectrodesLimit of Detection

Stichwörter der Autor:innen

electrochemical detectionheavy metalspig farm wastewater

Substanzen

WastewaterCopperZincWater Pollutants, Chemical

Autor:innen und Institutionen

  • Biofuels Institute and Institute for Energy Research, School of Environment and Safety Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China.

ORCID-Profile: Yang-Chun Yong

Zitieren

APA

Du, J. X., Ma, Y. H., Nawab, S., & Yong, Y. C. (2024). Simultaneous Electrochemical Detection of Cu2+ and Zn2+ in Pig Farm Wastewater. Sensors. https://doi.org/10.3390/s24082475

Vancouver

Du JX, Ma YH, Nawab S, Yong YC. Simultaneous Electrochemical Detection of Cu2+ and Zn2+ in Pig Farm Wastewater. Sensors. 2024. doi:10.3390/s24082475

BibTeX
@article{Du2024,
  author = {Du, Jia-Xin and Ma, Yang-Hao and Nawab, Said and Yong, Yang-Chun},
  title = {Simultaneous Electrochemical Detection of Cu2+ and Zn2+ in Pig Farm Wastewater},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24082475}
}
Kostenlos starten →