Near-InfraRed Spectroscopy Provides a Reproducible Estimate of Muscle Aerobic Capacity, but Not Whole-Body Aerobic Power
Sensors · 2024
DOI: 10.3390/s24072277 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Tomas Venckunas und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Sport Science and Innovations, Lithuanian Sports University, 44221 Kaunas, Lithuania. Hauptthemen laut MEDLINE: Spectroscopy, Near-Infrared, Quadriceps Muscle. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This research was funded by The Research Council of Lithuania, Research Council of Lithuania.
Abstract (Originalsprache)
Near-infrared spectroscopy (NIRS) during repeated limb occlusions is a noninvasive tool for assessing muscle oxidative capacity. However, the method’s reliability and validity remain under investigation. This study aimed to determine the reliability of the NIRS-derived mitochondrial power of the musculus vastus lateralis and its correlation with whole-body (cycling) aerobic power (V̇O2 peak). Eleven healthy active men (28 ± 10 y) twice (2 days apart) underwent repeated arterial occlusions to induce changes in muscle oxygen delivery after 15 s of electrical muscle stimulation. The muscle oxygen consumption (mV̇O2) recovery time and rate (k) constants were calculated from the NIRS O2Hb signal. We assessed the reliability (coefficient of variation and intraclass coefficient of correlation [ICC]) and equivalency (t-test) between visits. The results showed high reproducibility for the mV̇O2 recovery time constant (ICC = 0.859) and moderate reproducibility for the k value (ICC = 0.674), with no significant differences between visits (p > 0.05). NIRS-derived k did not correlate with the V̇O2 peak relative to body mass (r = 0.441, p = 0.17) or the absolute V̇O2 peak (r = 0.366, p = 0.26). In conclusion, NIRS provides a reproducible estimate of muscle mitochondrial power, which, however, was not correlated with whole-body aerobic capacity in the current study, suggesting that even if somewhat overlapping, not the same set of factors underpin these distinct indices of aerobic capacity at the different (peripheral and whole-body systemic) levels.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Sport Science and Innovations, Lithuanian Sports University, 44221 Kaunas, Lithuania.
- Department of Health Promotion and Rehabilitation, Lithuanian Sports University, 44221 Kaunas, Lithuania.
ORCID-Profile: Tomas Venckunas, Andrius Satas, Marius Brazaitis, Saule Sipaviciene
Förderung
- This research was funded by The Research Council of Lithuania
- Research Council of Lithuania
Zitieren
APA
Venckunas, T., Satas, A., Brazaitis, M., Eimantas, N., Sipaviciene, S., & Kamandulis, S. (2024). Near-InfraRed Spectroscopy Provides a Reproducible Estimate of Muscle Aerobic Capacity, but Not Whole-Body Aerobic Power. Sensors. https://doi.org/10.3390/s24072277
Vancouver
Venckunas T, Satas A, Brazaitis M, Eimantas N, Sipaviciene S, Kamandulis S. Near-InfraRed Spectroscopy Provides a Reproducible Estimate of Muscle Aerobic Capacity, but Not Whole-Body Aerobic Power. Sensors. 2024. doi:10.3390/s24072277
BibTeX
@article{Venckunas2024,
author = {Venckunas, Tomas and Satas, Andrius and Brazaitis, Marius and Eimantas, Nerijus and Sipaviciene, Saule and Kamandulis, Sigitas},
title = {Near-InfraRed Spectroscopy Provides a Reproducible Estimate of Muscle Aerobic Capacity, but Not Whole-Body Aerobic Power},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24072277}
}
EUVIMED