Validity and Practical Application of Muscle Oxygenation Monitoring for Identifying Maximal Fat Oxidation in Cyclists
European Journal of Sport Science · 2025
DOI: 10.1002/ejsc.70025 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift European Journal of Sport Science, 2025. Verfasst von Ander Romarate und 4 weiteren Autor:innen. Beteiligte Einrichtung: Emen4sport, Leioa, Spain. Hauptthemen laut MEDLINE: Bicycling, Oxygen Consumption, Muscle, Skeletal, Adipose Tissue. Die Arbeit nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The accurate detection of several physiological milestones, such as maximal fat oxidation (MFO), is an important factor for cycling performance and for programming effective and individualised training. However, the procedure to identify the MFO is often too complex and expensive. Near‐infrared spectroscopy (NIRS) technology provides a noninvasive measurement that can be used to detect different physiological variables. The aim of this study was to assess the validity of utilising the muscular oxygen saturation visualisation methodology for the identification of the MFO point in trained cyclists. Twenty‐two recreational endurance‐trained cyclists (19 men and 3 women; age: 27.9 ± 5.4 years; body mass: 69.7 ± 7.1 kg and VO 2max : 60.3 ± 7.0 mL/kg/min) performed a submaximal and maximal exhaustion test. All the data were collected on a single day. The validity of the visualisation methodology for the maximal fat oxidation point was analysed against a gas analyser. The detection of maximal fat oxidation (MFO) using the methodology and device employed does not appear to accurately specify the precise point at which MFO occurs (bias = 90 ± 218 s and LOA = 429 s). However, our results indicate that it may be a valid technique for identifying the MFO zone; biases were HR = 4.7 ± 11.9 bpm, VO 2 = 1.49 ± 5.7 mL/kg/min and power = 19.5 ± 31.2 W, whereas the concordance coefficients were 0.783, 0.243 and 0.170, respectively. It is not possible to detect MFO using NIRS device. However, it is possible to detect a general zone in which MFO occurs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Emen4sport, Leioa, Spain.
- Department of Physical Education and Sport, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain.
- Society, Sports, and Exercise Research Group (GIKAFIT), Department of Physical Education and Sport, Faculty of Education and Sport, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain.
- Research Group in Physical Activity, Physical Exercise and Sport (AKTIBOki), Department of Physical Education and Sport, Faculty of Education and Sport, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain.
- Institute of Sport Science, University of Bern, Bern, Switzerland.
- Glut4Science, Physiology, Nutrition and Sport, Vitoria-Gasteiz, Spain.
ORCID-Profile: Aitor Pinedo-Jauregi, Andri Feldmann, Jordan Santos-Concejero
Zitieren
APA
Romarate, A., Pinedo-Jauregi, A., Feldmann, A., Viribay, A., & Santos-Concejero, J. (2025). Validity and Practical Application of Muscle Oxygenation Monitoring for Identifying Maximal Fat Oxidation in Cyclists. European Journal of Sport Science. https://doi.org/10.1002/ejsc.70025
Vancouver
Romarate A, Pinedo-Jauregi A, Feldmann A, Viribay A, Santos-Concejero J. Validity and Practical Application of Muscle Oxygenation Monitoring for Identifying Maximal Fat Oxidation in Cyclists. European Journal of Sport Science. 2025. doi:10.1002/ejsc.70025
BibTeX
@article{Romarate2025,
author = {Romarate, Ander and Pinedo-Jauregi, Aitor and Feldmann, Andri and Viribay, Aitor and Santos-Concejero, Jordan},
title = {Validity and Practical Application of Muscle Oxygenation Monitoring for Identifying Maximal Fat Oxidation in Cyclists},
journal = {European Journal of Sport Science},
year = {2025},
doi = {10.1002/ejsc.70025}
}
EUVIMED