Fachartikel in der Zeitschrift Sensors, online erschienen am 23.03.2024. Verfasst von Shaocan Fan und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronics and Communication Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen 518107, China. Hauptthemen laut MEDLINE: Thoracic Wall. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science, Technology and Innovation Commission of Shenzhen Municipality, Science and Technology Planning Project of Key Laboratory of Advanced IntelliSense Technology, Guangdong Science and Technology Department, Science and Technology Planning Project of the Key Laboratory of Advanced IntelliSense Technology, Guangdong Science and Technology Department.
Abstract (Originalsprache)
An increasing number of studies on non-contact vital sign detection using radar are now beginning to turn to data-driven neural network approaches rather than traditional signal-processing methods. However, there are few radar datasets available for deep learning due to the difficulty of acquiring and labeling the data, which require specialized equipment and physician collaboration. This paper presents a new model of heartbeat-induced chest wall motion (CWM) with the goal of generating a large amount of simulation data to support deep learning methods. An in-depth analysis of published CWM data collected by the VICON Infrared (IR) motion capture system and continuous wave (CW) radar system during respiratory hold was used to summarize the motion characteristics of each stage within a cardiac cycle. In combination with the physiological properties of the heartbeat, appropriate mathematical functions were selected to describe these movement properties. The model produced simulation data that closely matched the measured data as evaluated by dynamic time warping (DTW) and the root-mean-squared error (RMSE). By adjusting the model parameters, the heartbeat signals of different individuals were simulated. This will accelerate the application of data-driven deep learning methods in radar-based non-contact vital sign detection research and further advance the field.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Electronics and Communication Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen 518107, China.
ORCID-Profile: Shaocan Fan, Zhenmiao Deng
Förderung
- Science, Technology and Innovation Commission of Shenzhen Municipality
- Science and Technology Planning Project of Key Laboratory of Advanced IntelliSense Technology, Guangdong Science and Technology Department
- Science and Technology Planning Project of the Key Laboratory of Advanced IntelliSense Technology, Guangdong Science and Technology Department
Zitieren
APA
Fan, S., & Deng, Z. (2024). Chest Wall Motion Model of Cardiac Activity for Radar-Based Vital-Sign-Detection System. Sensors, 24(7), 2058. https://doi.org/10.3390/s24072058
Vancouver
Fan S, Deng Z. Chest Wall Motion Model of Cardiac Activity for Radar-Based Vital-Sign-Detection System. Sensors. 2024;24(7):2058. doi:10.3390/s24072058
BibTeX
@article{Fan2024,
author = {Fan, Shaocan and Deng, Zhenmiao},
title = {Chest Wall Motion Model of Cardiac Activity for Radar-Based Vital-Sign-Detection System},
journal = {Sensors},
year = {2024},
volume = {24},
number = {7},
pages = {2058},
doi = {10.3390/s24072058}
}
EUVIMED