Flexible Textile Sensors-Based Smart T-Shirt for Respiratory Monitoring: Design, Development, and Preliminary Validation
Sensors · 21.03.2024 · 24 (6) · 2018
DOI: 10.3390/s24062018 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 21.03.2024. Verfasst von Chiara Romano und 4 weiteren Autor:innen. Beteiligte Einrichtung: Research Unit of Measurements and Biomedical Instrumentation, Departmental of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Porti…. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Running. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union-Next Generation, European Union, European Union–Next Generation EU–NRRP M4.C2–Investment 1.5 Establishing and Strengthening of Innovation Ecosystems for Sustainability (Rome Technopole).
Abstract (Originalsprache)
Respiratory rate (fR) monitoring through wearable devices is crucial in several scenarios, providing insights into well-being and sports performance while minimizing interference with daily activities. Strain sensors embedded into garments stand out but require thorough investigation for optimal deployment. Optimal sensor positioning is often overlooked, and when addressed, the quality of the respiratory signal is neglected. Additionally, sensor metrological characterization after sensor integration is often omitted. In this study, we present the design, development, and feasibility assessment of a smart t-shirt embedded with two flexible sensors for fR monitoring. Guided by a motion capture system, optimal sensor design and position on the chest wall were defined, considering both signal magnitude and quality. The sensors were developed, embedded into the wearable system, and metrologically characterized, demonstrating a remarkable response to both static (sensitivity 9.4 Ω⋅%−1 and 9.1 Ω⋅%−1 for sensor A and sensor B, respectively) and cyclic loads (min. hysteresis span 20.4% at 36 bpm obtained for sensor A). The feasibility of the wearable system was assessed on healthy volunteers both under static and dynamic conditions (such as running, walking, and climbing stairs). A mean absolute error of 0.32 bpm was obtained by averaging all subjects and tests using the combination of the two sensors. This value was lower than that obtained using both sensor A (0.53 bpm) and sensor B (0.78 bpm) individually. Our study highlights the importance of signal amplitude and quality in optimal sensor placement evaluation, as well as the characterization of the embedded sensors for metrological assessment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research Unit of Measurements and Biomedical Instrumentation, Departmental of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy.
- Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128 Rome, Italy.
ORCID-Profile: Chiara Romano, Sergio Silvestri, Emiliano Schena, Carlo Massaroni
Förderung
- European Union-Next Generation
- European Union
- European Union–Next Generation EU–NRRP M4.C2–Investment 1.5 Establishing and Strengthening of Innovation Ecosystems for Sustainability (Rome Technopole)
- European project PROVIDE (“Prediction and prevention of cardiovascular diseases in pre- and type 2 diabetes”)
Zitieren
APA
Romano, C., Lo Presti, D., Silvestri, S., Schena, E., & Massaroni, C. (2024). Flexible Textile Sensors-Based Smart T-Shirt for Respiratory Monitoring: Design, Development, and Preliminary Validation. Sensors, 24(6), 2018. https://doi.org/10.3390/s24062018
Vancouver
Romano C, Lo Presti D, Silvestri S, Schena E, Massaroni C. Flexible Textile Sensors-Based Smart T-Shirt for Respiratory Monitoring: Design, Development, and Preliminary Validation. Sensors. 2024;24(6):2018. doi:10.3390/s24062018
BibTeX
@article{Romano2024,
author = {Romano, Chiara and Lo Presti, Daniela and Silvestri, Sergio and Schena, Emiliano and Massaroni, Carlo},
title = {Flexible Textile Sensors-Based Smart T-Shirt for Respiratory Monitoring: Design, Development, and Preliminary Validation},
journal = {Sensors},
year = {2024},
volume = {24},
number = {6},
pages = {2018},
doi = {10.3390/s24062018}
}