EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Knee Angle Estimation with Dynamic Calibration Using Inertial Measurement Units for Running

Matthew B Rhudy iD, Joseph M Mahoney iD, Allison R Altman-Singles

Sensors · 2024

DOI: 10.3390/s24020695 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Sensors, 2024. Verfasst von Matthew B Rhudy und 2 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical Engineering, The Pennsylvania State University, Berks College, Reading, PA 19610, USA. Hauptthemen laut MEDLINE: Knee, Knee Joint. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The knee flexion angle is an important measurement for studies of the human gait. Running is a common activity with a high risk of knee injury. Studying the running gait in realistic situations is challenging because accurate joint angle measurements typically come from optical motion-capture systems constrained to laboratory settings. This study considers the use of shank and thigh inertial sensors within three different filtering algorithms to estimate the knee flexion angle for running without requiring sensor-to-segment mounting assumptions, body measurements, specific calibration poses, or magnetometers. The objective of this study is to determine the knee flexion angle within running applications using accelerometer and gyroscope information only. Data were collected for a single test participant (21-year-old female) at four different treadmill speeds and used to validate the estimation results for three filter variations with respect to a Vicon optical motion-capture system. The knee flexion angle filtering algorithms resulted in root-mean-square errors of approximately three degrees. The results of this study indicate estimation results that are within acceptable limits of five degrees for clinical gait analysis. Specifically, a complementary filter approach is effective for knee flexion angle estimation in running applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KneeKnee JointFemaleHumansYoung AdultBiomechanical PhenomenaCalibrationGait

Stichwörter der Autor:innen

Kalman filteringgait analysisinertial measurement unitskinematic constraints

Autor:innen und Institutionen

  • Mechanical Engineering, The Pennsylvania State University, Berks College, Reading, PA 19610, USA.
  • Mechanical Engineering, Alvernia University, Reading, PA 19607, USA.
  • Kinesiology, The Pennsylvania State University, Berks College, Reading, PA 19610, USA.

ORCID-Profile: Matthew B Rhudy, Joseph M Mahoney

Zitieren

APA

Rhudy, M. B., Mahoney, J. M., & Altman-Singles, A. R. (2024). Knee Angle Estimation with Dynamic Calibration Using Inertial Measurement Units for Running. Sensors. https://doi.org/10.3390/s24020695

Vancouver

Rhudy MB, Mahoney JM, Altman-Singles AR. Knee Angle Estimation with Dynamic Calibration Using Inertial Measurement Units for Running. Sensors. 2024. doi:10.3390/s24020695

BibTeX
@article{Rhudy2024,
  author = {Rhudy, Matthew B and Mahoney, Joseph M and Altman-Singles, Allison R},
  title = {Knee Angle Estimation with Dynamic Calibration Using Inertial Measurement Units for Running},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24020695}
}
Kostenlos starten →