Establishing thresholds for swing transparency at the knee during gait to inform exoskeleton design
PLOS ONE · 17.01.2025 · 20 (1) · e0317259
DOI: 10.1371/journal.pone.0317259 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 17.01.2025. Verfasst von Chase W Mathews und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, United States of America. Hauptthemen laut MEDLINE: Gait, Exoskeleton Device, Knee Joint, Knee. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Knee exoskeletons have been developed to assist, stabilize, or improve human movement or recovery. However, exoskeleton designers must implement transparency (i.e., get out of the way) modes during the swing phase of locomotor tasks to avoid impeding movement. The problem is that it is not understood how sensitive people are to small knee torques or what level of knee impedance is acceptable (sufficiently transparent) during swing phase. Here, we (i) characterized the biomechanical consequences of knee stiffness and damping during swing, and (ii) leveraged user perceptions of being impeded and toe clearance to define transparency thresholds, below which the participants were sufficiently unimpeded during the swing phase of gait. We conducted a series of human subject experiments that involved walking and stair ascent/descent while wearing a modified knee brace with five stiffness values ranging from 0 to 4 Nm/rad and five damping values ranging from 0 to 0.77 Nm/rad/s. We measured changes to lower limb kinematics, knee flexor muscle activity, and participants’ perception of being impeded during swing. Kinematics, muscle activity, and perceived impedance all changed in response to added stiffness and damping. For stiffness, we found the median transparency thresholds for walking and stairs to be 1.76 Nm/rad and 2.95 Nm/rad, respectively, which corresponds to peak knee moments during swing of around 2.3 and 5 Nm. For damping, we found the median transparency threshold for walking and stairs to be about the same, 0.29 Nm/rad/s, which corresponds to peak knee moments during swing of around 2.3 Nm. These values provide useful benchmarks for defining quantitative design requirements for knee exoskeletons intended for locomotor activities.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, United States of America.
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, United States of America.
- Department of Physical Medicine and Rehabilitation, Vanderbilt University, Nashville, TN, United States of America.
ORCID-Profile: Chase W Mathews, Delaney A Clawson
Zitieren
APA
Mathews, C. W., Clawson, D. A., & Zelik, K. E. (2025). Establishing thresholds for swing transparency at the knee during gait to inform exoskeleton design. PLOS ONE, 20(1), e0317259. https://doi.org/10.1371/journal.pone.0317259
Vancouver
Mathews CW, Clawson DA, Zelik KE. Establishing thresholds for swing transparency at the knee during gait to inform exoskeleton design. PLOS ONE. 2025;20(1):e0317259. doi:10.1371/journal.pone.0317259
BibTeX
@article{Mathews2025,
author = {Mathews, Chase W and Clawson, Delaney A and Zelik, Karl E},
title = {Establishing thresholds for swing transparency at the knee during gait to inform exoskeleton design},
journal = {PLOS ONE},
year = {2025},
volume = {20},
number = {1},
pages = {e0317259},
doi = {10.1371/journal.pone.0317259}
}