A Novel Signal Restoration Method of Noisy Photoplethysmograms for Uninterrupted Health Monitoring
Sensors · 26.12.2023 · 24 (1) · 141
DOI: 10.3390/s24010141 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 26.12.2023. Verfasst von Aikaterini Vraka und 5 weiteren Autor:innen. Beteiligte Einrichtung: Biosignals and Minimally Invasive Technologies (BioMIT.org), Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, …. Hauptthemen laut MEDLINE: Photoplethysmography, Algorithms. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Agencia Estatal de Investigación, Joint Funding of Spanish Government and European Regional Development Fund, Junta de Comunidades de Castilla-La Mancha.
Abstract (Originalsprache)
Health-tracking from photoplethysmography (PPG) signals is significantly hindered by motion artifacts (MAs). Although many algorithms exist to detect MAs, the corrupted signal often remains unexploited. This work introduces a novel method able to reconstruct noisy PPGs and facilitate uninterrupted health monitoring. The algorithm starts with spectral-based MA detection, followed by signal reconstruction by using the morphological and heart-rate variability information from the clean segments adjacent to noise. The algorithm was tested on (a) 30 noisy PPGs of a maximum 20 s noise duration and (b) 28 originally clean PPGs, after noise addition (2–120 s) (1) with and (2) without cancellation of the corresponding clean segment. Sampling frequency was 250 Hz after resampling. Noise detection was evaluated by means of accuracy, sensitivity, and specificity. For the evaluation of signal reconstruction, the heart-rate (HR) was compared via Pearson correlation (PC) and absolute error (a) between ECGs and reconstructed PPGs and (b) between original and reconstructed PPGs. Bland-Altman (BA) analysis for the differences in HR estimation on original and reconstructed segments of (b) was also performed. Noise detection accuracy was 90.91% for (a) and 99.38–100% for (b). For the PPG reconstruction, HR showed 99.31% correlation in (a) and >90% for all noise lengths in (b). Mean absolute error was 1.59 bpm for (a) and 1.26–1.82 bpm for (b). BA analysis indicated that, in most cases, 90% or more of the recordings fall within the confidence interval, regardless of the noise length. Optimal performance is achieved even for signals of noise up to 2 min, allowing for the utilization and further analysis of recordings that would otherwise be discarded. Thereby, the algorithm can be implemented in monitoring devices, assisting in uninterrupted health-tracking.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biosignals and Minimally Invasive Technologies (BioMIT.org), Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain.
- Research Group in Electronic, Biomedical and Telecommunication Engineering, University of Castilla-La Mancha, 16071 Cuenca, Spain.
- Arrhythmia Unit, Cardiology Department, General University Hospital Consortium of Valencia, 46014 Valencia, Spain.
- Cardiovascular Surgery Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain.
ORCID-Profile: Aikaterini Vraka, Roberto Zangróniz, Aurelio Quesada, Fernando Hornero, Raúl Alcaraz, José J Rieta
Förderung
- Agencia Estatal de Investigación
- Joint Funding of Spanish Government and European Regional Development Fund
- Junta de Comunidades de Castilla-La Mancha
- Generalitat Valenciana
- Spanish Government
- 10.13039/501100011033 jointly with the European Regional Development Fund (EU)
Zitieren
APA
Vraka, A., Zangróniz, R., Quesada, A., Hornero, F., Alcaraz, R., & Rieta, J. J. (2023). A Novel Signal Restoration Method of Noisy Photoplethysmograms for Uninterrupted Health Monitoring. Sensors, 24(1), 141. https://doi.org/10.3390/s24010141
Vancouver
Vraka A, Zangróniz R, Quesada A, Hornero F, Alcaraz R, Rieta JJ. A Novel Signal Restoration Method of Noisy Photoplethysmograms for Uninterrupted Health Monitoring. Sensors. 2023;24(1):141. doi:10.3390/s24010141
BibTeX
@article{Vraka2023,
author = {Vraka, Aikaterini and Zangróniz, Roberto and Quesada, Aurelio and Hornero, Fernando and Alcaraz, Raúl and Rieta, José J},
title = {A Novel Signal Restoration Method of Noisy Photoplethysmograms for Uninterrupted Health Monitoring},
journal = {Sensors},
year = {2023},
volume = {24},
number = {1},
pages = {141},
doi = {10.3390/s24010141}
}