Novel Calibration Approach for Monitoring Aerosol Hydrogen Isotopes Using Laser-Induced Breakdown Spectroscopy for Molten Salt Reactor Off-Gas Streams
Sensors · 13.12.2023 · 23 (24) · 9797
DOI: 10.3390/s23249797 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 13.12.2023. Verfasst von Hunter B Andrews und 1 weiteren Autor:innen. Beteiligte Einrichtung: Radioisotope Science and Technology Division, Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37831, USA. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: US Department of Energy’s Office of Nuclear Energy, Advanced Reactor Development Program, Molten Salt Reactor Program, UT-Battelle, LLC.
Abstract (Originalsprache)
Online monitoring is a key challenge for the continued development of molten salt reactor (MSR) technology. Laser-induced breakdown spectroscopy (LIBS) has previously been demonstrated to be a viable tool for monitoring aerosolized species and noble gases in real time, but the ability to discern varying isotopes in these streams has not yet been investigated for MSR applications. Tritium will form in MSRs from ternary fission and from (n,α)-reactions occurring in lithium-containing salts. This study compares three spectrometers of varying resolutions and types for measuring hydrogen isotope shifts in LIBS spectra of wetted filter paper. For each spectrometer, multivariate models were built (i.e., principal component regression, partial least squares regression, and multivariate curve resolution) to quantify the isotope ratio. The top models were then modified and corrected to apply the models to aerosol samples with varying isotope ratios. This novel calibration strategy offers an 82% reduction in volume of the calibration samples needed and is a more viable pathway for calibrating deployable LIBS systems. Lastly, this calibration model was compared with an all-aerosol trained model for monitoring hydrogen isotopes during a real-time test where the protium/deuterium ratio, along with representative salt species (i.e., lithium, sodium, and potassium) were adjusted dynamically. Results of this test validated the predictive capabilities of the transferred model and highlighted the capabilities of LIBS for real-time monitoring of MSR effluent streams.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radioisotope Science and Technology Division, Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37831, USA.
- Nuclear Energy and Fuel Cycle Division, Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37831, USA.
ORCID-Profile: Hunter B Andrews, Joanna McFarlane
Förderung
- US Department of Energy’s Office of Nuclear Energy, Advanced Reactor Development Program, Molten Salt Reactor Program
- UT-Battelle, LLC
Zitieren
APA
Andrews, H. B., & McFarlane, J. (2023). Novel Calibration Approach for Monitoring Aerosol Hydrogen Isotopes Using Laser-Induced Breakdown Spectroscopy for Molten Salt Reactor Off-Gas Streams. Sensors, 23(24), 9797. https://doi.org/10.3390/s23249797
Vancouver
Andrews HB, McFarlane J. Novel Calibration Approach for Monitoring Aerosol Hydrogen Isotopes Using Laser-Induced Breakdown Spectroscopy for Molten Salt Reactor Off-Gas Streams. Sensors. 2023;23(24):9797. doi:10.3390/s23249797
BibTeX
@article{Andrews2023,
author = {Andrews, Hunter B and McFarlane, Joanna},
title = {Novel Calibration Approach for Monitoring Aerosol Hydrogen Isotopes Using Laser-Induced Breakdown Spectroscopy for Molten Salt Reactor Off-Gas Streams},
journal = {Sensors},
year = {2023},
volume = {23},
number = {24},
pages = {9797},
doi = {10.3390/s23249797}
}
EUVIMED