EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Label-Free Detection of CA19-9 Using a BSA/Graphene-Based Antifouling Electrochemical Immunosensor

Wei Chen, Miaomiao Chi, Miaomiao Wang, Yage Liu, Shu Kong, Liping Du, Jian Wang, Chunsheng Wu iD

Sensors · 2023

DOI: 10.3390/s23249693 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Wei Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an…. Hauptthemen laut MEDLINE: Graphite, Biosensing Techniques, Biofouling. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Evaluating the levels of the biomarker carbohydrate antigen 19-9 (CA19-9) is crucial in early cancer diagnosis and prognosis assessment. In this study, an antifouling electrochemical immunosensor was developed for the label-free detection of CA19-9, in which bovine serum albumin (BSA) and graphene were cross-linked with the aid of glutaraldehyde to form a 3D conductive porous network on the surface of an electrode. The electrochemical immunosensor was characterized through the use of transmission electron microscopy (TEM), scanning electron microscopy (SEM), atomic force microscope (AFM), UV spectroscopy, and electrochemical methods. The level of CA19-9 was determined through the use of label-free electrochemical impedance spectroscopy (EIS) measurements. The electron transfer at the interface of the electrode was well preserved in human serum samples, demonstrating that this electrochemical immunosensor has excellent antifouling performance. CA19-9 could be detected in a wide range from 13.5 U/mL to 1000 U/mL, with a detection limit of 13.5 U/mL in human serum samples. This immunosensor also exhibited good selectivity and stability. The detection results of this immunosensor were further validated and compared using an enzyme-linked immunosorbent assay (ELISA). All the results confirmed that this immunosensor has a good sensing performance in terms of CA19-9, suggesting its promising application prospects in clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteBiosensing TechniquesBiofoulingHumansCA-19-9 AntigenSerum Albumin, BovineImmunoassayElectrochemical TechniquesLimit of DetectionGold

Stichwörter der Autor:innen

CA19-9antifoulingelectrochemical immunosensorelectrochemical impedance spectroscopygraphene

Substanzen

GraphiteCA-19-9 AntigenSerum Albumin, BovineGold

Autor:innen und Institutionen

  • Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China.

ORCID-Profile: Chunsheng Wu

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Chen, W., Chi, M., Wang, M., Liu, Y., Kong, S., Du, L., Wang, J., & Wu, C. (2023). Label-Free Detection of CA19-9 Using a BSA/Graphene-Based Antifouling Electrochemical Immunosensor. Sensors. https://doi.org/10.3390/s23249693

Vancouver

Chen W, Chi M, Wang M, Liu Y, Kong S, Du L, et al. Label-Free Detection of CA19-9 Using a BSA/Graphene-Based Antifouling Electrochemical Immunosensor. Sensors. 2023. doi:10.3390/s23249693

BibTeX
@article{Chen2023,
  author = {Chen, Wei and Chi, Miaomiao and Wang, Miaomiao and Liu, Yage and Kong, Shu and Du, Liping and Wang, Jian and Wu, Chunsheng},
  title = {Label-Free Detection of CA19-9 Using a BSA/Graphene-Based Antifouling Electrochemical Immunosensor},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23249693}
}
Kostenlos starten →