EUVIMEDEUVIMED entdecken
Crossref

Eutectogel-Based Antifouling Interface: Addressing Sensitivity and Accuracy Challenges in Complex Serum

Xingxin Shi, Jiawei Li, Jianquan Shen, Hongliang Han, Zhanfang Ma iD

Analytical Chemistry · 2026

DOI: 10.1021/acs.analchem.5c08188 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Xingxin Shi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Capital Normal University, Beijing 100048, China. Hauptthemen laut MEDLINE: Electrochemical Techniques, Biofouling, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nonspecific adsorption in complex biological matrices remains a major challenge for the clinical application of electrochemical biosensors. Although various antifouling strategies have been developed to resist nonspecific adsorption, their poor conductivity and inadequate stability create substantial challenges for sensor sensitivity and accuracy in complex serum samples. To address these issues, we present a multifunctional eutectogel with excellent antifouling capability, conductivity, and stability, enabling ultrasensitive and reliable electrochemical sensing in a complex serum. The eutectogel was synthesized using choline chloride/ethylene glycol as the solvent, carboxybetaine methacrylate (CBMA) and sulfobetaine methacrylate (SBMA) as monomers, and liquid metal nanoparticle-decorated reduced graphene oxide (LMNPs@rGO) as both the initiator and the conductive component. The resulting eutectogel exhibits excellent conductivity of 0.9546 S·m-1 along with superior antifouling performance. After incubation in undiluted serum for 2 h, the impedance change rate of the modified electrode was reduced by ∼4.68-fold compared to a BSA-modified electrode, and the antifouling performance remained stable even after continuous incubation for 72 h. Using carbohydrate antigen 19-9 as a model biomarker, the constructed sensor achieved a wide linear detection range (10 μU·mL-1 to 100 U·mL-1) and an ultralow detection limit (0.4554 μU·mL-1), which is 2-3 orders of magnitude lower than previously reported values. The proposed eutectogel-based sensor enables ultrasensitive and reliable detection of trace tumor biomarkers in complex serum, offering broad prospects for early cancer diagnosis, prognosis monitoring, and clinical application.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrochemical TechniquesBiofoulingBiosensing TechniquesGraphiteGelsHumansElectrodesBetaineMetal NanoparticlesAnimalsLimit of DetectionMethacrylatesCholine

Substanzen

GraphiteGelsBetainegraphene oxideMethacrylatesCholine

Autor:innen und Institutionen

  • Department of Chemistry, Capital Normal University, Beijing 100048, China.
  • Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.

ORCID-Profile: Zhanfang Ma

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Shi, X., Li, J., Shen, J., Han, H., & Ma, Z. (2026). Eutectogel-Based Antifouling Interface: Addressing Sensitivity and Accuracy Challenges in Complex Serum. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c08188

Vancouver

Shi X, Li J, Shen J, Han H, Ma Z. Eutectogel-Based Antifouling Interface: Addressing Sensitivity and Accuracy Challenges in Complex Serum. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.5c08188

BibTeX
@article{Shi2026,
  author = {Shi, Xingxin and Li, Jiawei and Shen, Jianquan and Han, Hongliang and Ma, Zhanfang},
  title = {Eutectogel-Based Antifouling Interface: Addressing Sensitivity and Accuracy Challenges in Complex Serum},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.5c08188}
}
Kostenlos starten →