Damage Mechanism of HgCdTe Focal Plane Array Detector Irradiated Using Mid-Infrared Pulse Laser
Sensors · 23.11.2023 · 23 (23) · 9370
DOI: 10.3390/s23239370 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 23.11.2023. Verfasst von Yin Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Laser Interaction with Matter, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changc…. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Defense Pre-Research Foundation of China, Fundamental Research Project of Chinese State Key Laboratory of Laser Inter-action with Matter.
Abstract (Originalsprache)
To investigate the damage threshold and mechanism of a mid-infrared HgCdTe focal plane array (FPA) detector, relevant experimental and theoretical studies were conducted. The line damage threshold of a HgCdTe FPA detector may be within the range of 0.59 Jcm−2 to 0.71 Jcm−2. The full frame damage threshold of the detector may be in the range of 0.86 Jcm−2 to 1.17 Jcm−2. Experimental results showed that when the energy density reaches 1.17 Jcm−2, the detector exhibits irreversible full frame damage and is completely unable to image. Based on the finite element method, a three-dimensional model of HgCdTe FPAs detector was established to study the heat transfer mechanism, internal stress, and damage sequence. When HgCdTe melts, we think that the detector is damaged. Under these conditions, the theoretical damage threshold calculated using the detector model is 0.55 Jcm−2. The difference between theoretical and experimental values was analyzed. The relationship between damage threshold and pulse width was also studied. It was found that when the pulse width is less than 1000 ns, the damage threshold characterized by peak power density is inversely proportional to pulse width. This relationship can help us predict the experimental damage threshold of an FPA detector. This model is reasonable and convenient for studying the damage of FPA detectors with a mid-infrared pulse laser. The research content in this article has important reference significance for the damage and protection of HgCdTe FPA detectors.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Laser Interaction with Matter, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130022, China.
- University of Chinese Academy of Sciences, Beijing 100049, China.
Förderung
- National Defense Pre-Research Foundation of China
- Fundamental Research Project of Chinese State Key Laboratory of Laser Inter-action with Matter
Zitieren
APA
Zhang, Y., Zheng, C., Liu, Y., Wang, Y., Xu, Y., & Shao, J. (2023). Damage Mechanism of HgCdTe Focal Plane Array Detector Irradiated Using Mid-Infrared Pulse Laser. Sensors, 23(23), 9370. https://doi.org/10.3390/s23239370
Vancouver
Zhang Y, Zheng C, Liu Y, Wang Y, Xu Y, Shao J. Damage Mechanism of HgCdTe Focal Plane Array Detector Irradiated Using Mid-Infrared Pulse Laser. Sensors. 2023;23(23):9370. doi:10.3390/s23239370
BibTeX
@article{Zhang2023,
author = {Zhang, Yin and Zheng, Changbin and Liu, Yang and Wang, Yunzhe and Xu, Yongbo and Shao, Junfeng},
title = {Damage Mechanism of HgCdTe Focal Plane Array Detector Irradiated Using Mid-Infrared Pulse Laser},
journal = {Sensors},
year = {2023},
volume = {23},
number = {23},
pages = {9370},
doi = {10.3390/s23239370}
}
EUVIMED