A Wearable Force Myography-Based Armband for Recognition of Upper Limb Gestures
Sensors · 23.11.2023 · 23 (23) · 9357
DOI: 10.3390/s23239357 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 23.11.2023. Verfasst von Mustafa Ur Rehman und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechatronics Engineering, University of Engineering and Technology Peshawar, Peshawar 25000, Pakistan. Hauptthemen laut MEDLINE: Gestures, Wearable Electronic Devices. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deanship of Scientific Research, Vice Presidency for Graduate Studies and Scientific Research, King Faisal University, Saudi Arabia.
Abstract (Originalsprache)
Force myography (FMG) represents a promising alternative to surface electromyography (EMG) in the context of controlling bio-robotic hands. In this study, we built upon our prior research by introducing a novel wearable armband based on FMG technology, which integrates force-sensitive resistor (FSR) sensors housed in newly designed casings. We evaluated the sensors’ characteristics, including their load–voltage relationship and signal stability during the execution of gestures over time. Two sensor arrangements were evaluated: arrangement A, featuring sensors spaced at 4.5 cm intervals, and arrangement B, with sensors distributed evenly along the forearm. The data collection involved six participants, including three individuals with trans-radial amputations, who performed nine upper limb gestures. The prediction performance was assessed using support vector machines (SVMs) and k-nearest neighbor (KNN) algorithms for both sensor arrangments. The results revealed that the developed sensor exhibited non-linear behavior, and its sensitivity varied with the applied force. Notably, arrangement B outperformed arrangement A in classifying the nine gestures, with an average accuracy of 95.4 ± 2.1% compared to arrangement A’s 91.3 ± 2.3%. The utilization of the arrangement B armband led to a substantial increase in the average prediction accuracy, demonstrating an improvement of up to 4.5%.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechatronics Engineering, University of Engineering and Technology Peshawar, Peshawar 25000, Pakistan.
- Department of Mechanical Engineering, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
- Department of Information Systems, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
ORCID-Profile: Mustafa Ur Rehman, Kamran Shah
Förderung
- Deanship of Scientific Research, Vice Presidency for Graduate Studies and Scientific Research, King Faisal University, Saudi Arabia
Zitieren
APA
Rehman, M. U., Shah, K., Haq, I. U., Iqbal, S., & Ismail, M. A. (2023). A Wearable Force Myography-Based Armband for Recognition of Upper Limb Gestures. Sensors, 23(23), 9357. https://doi.org/10.3390/s23239357
Vancouver
Rehman MU, Shah K, Haq IU, Iqbal S, Ismail MA. A Wearable Force Myography-Based Armband for Recognition of Upper Limb Gestures. Sensors. 2023;23(23):9357. doi:10.3390/s23239357
BibTeX
@article{Rehman2023,
author = {Rehman, Mustafa Ur and Shah, Kamran and Haq, Izhar Ul and Iqbal, Sajid and Ismail, Mohamed A},
title = {A Wearable Force Myography-Based Armband for Recognition of Upper Limb Gestures},
journal = {Sensors},
year = {2023},
volume = {23},
number = {23},
pages = {9357},
doi = {10.3390/s23239357}
}