Assessment of Low-Density Force Myography Armband for Classification of Upper Limb Gestures
Sensors · 2023
DOI: 10.3390/s23052716 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Mustafa Ur Rehman und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechatronics Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan. Hauptthemen laut MEDLINE: Gestures, Upper Extremity. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Faisal University, Saudi Arabia, Deanship of Scientific Research, Vice Presidency for Graduate studies and Scientific Research, King Faisal University, Saudi Arabia.
Abstract (Originalsprache)
Using force myography (FMG) to monitor volumetric changes in limb muscles is a promising and effective alternative for controlling bio-robotic prosthetic devices. In recent years, there has been a focus on developing new methods to improve the performance of FMG technology in the control of bio-robotic devices. This study aimed to design and evaluate a novel low-density FMG (LD-FMG) armband for controlling upper limb prostheses. The study investigated the number of sensors and sampling rate for the newly developed LD-FMG band. The performance of the band was evaluated by detecting nine gestures of the hand, wrist, and forearm at varying elbow and shoulder positions. Six subjects, including both fit and amputated individuals, participated in this study and completed two experimental protocols: static and dynamic. The static protocol measured volumetric changes in forearm muscles at the fixed elbow and shoulder positions. In contrast, the dynamic protocol included continuous motion of the elbow and shoulder joints. The results showed that the number of sensors significantly impacts gesture prediction accuracy, with the best accuracy achieved on the 7-sensor FMG band arrangement. Compared to the number of sensors, the sampling rate had a lower influence on prediction accuracy. Additionally, variations in limb position greatly affect the classification accuracy of gestures. The static protocol shows an accuracy above 90% when considering nine gestures. Among dynamic results, shoulder movement shows the least classification error compared to elbow and elbow–shoulder (ES) movements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechatronics Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan.
- Department of Mechanical Engineering, King Faisal University, Al-Hofuf 31982, Saudi Arabia.
- Department of Information Systems, King Faisal University, Al-Hofuf 31982, Saudi Arabia.
ORCID-Profile: Mustafa Ur Rehman, Mohamed A Ismail
Förderung
- King Faisal University, Saudi Arabia
- Deanship of Scientific Research, Vice Presidency for Graduate studies and Scientific Research, King Faisal University, Saudi Arabia
Zitieren
APA
Rehman, M. U., Shah, K., Haq, I. U., Iqbal, S., Ismail, M. A., & Selimefendigil, F. (2023). Assessment of Low-Density Force Myography Armband for Classification of Upper Limb Gestures. Sensors. https://doi.org/10.3390/s23052716
Vancouver
Rehman MU, Shah K, Haq IU, Iqbal S, Ismail MA, Selimefendigil F. Assessment of Low-Density Force Myography Armband for Classification of Upper Limb Gestures. Sensors. 2023. doi:10.3390/s23052716
BibTeX
@article{Rehman2023,
author = {Rehman, Mustafa Ur and Shah, Kamran and Haq, Izhar Ul and Iqbal, Sajid and Ismail, Mohamed A and Selimefendigil, Fatih},
title = {Assessment of Low-Density Force Myography Armband for Classification of Upper Limb Gestures},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23052716}
}
EUVIMED