EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ultrasonic Thickness Measurement Method and System Implementation Based on Sampling Reconstruction and Phase Feature Extraction

Wenqiang Gong, Xuanze Wang, Zhenyu Yang, Zhongsheng Zhai, Wei Feng iD, Da Liu

Sensors · 09.11.2023 · 23 (22) · 9072

DOI: 10.3390/s23229072 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 09.11.2023. Verfasst von Wenqiang Gong und 5 weiteren Autor:innen. Beteiligte Einrichtung: Hubei Key Laboratory of Modern Manufacturing Quantity Engineering, College of Mechanical Engineering, Hubei University of Technology, Wuhan 430068, C…. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Natural Science Foundation of China, Hubei Natural Science Foundation, Wuhan Keyresearch and development plan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The existing ultrasonic thickness measurement systems require high sampling frequencies for echo signal acquisition, leading to complex circuit designs and high costs. Moreover, extracting the characteristics of ultrasonic echo signals for accurate thickness measurement poses significant challenges. To address these issues, this paper proposes a method that utilizes conventional sampling frequencies to acquire high-frequency ultrasonic echo signals, overcoming the limitations of high-frequency data acquisition imposed by the Nyquist–Shannon sampling theorem. By employing an improved sampling reconstruction technique, the multi-cycle sampling signals are reconstructed and rearranged within a single cycle, effectively increasing the equivalent sampling frequency. Additionally, a combination of coarse estimation using fast Fourier transform (FFT) and precise phase extraction using the moving sine fitting algorithm is proposed for accurate thickness measurement, resolving the limitations of common thickness measurement methods such as peak detection, envelope detection, and Hilbert autocorrelation in terms of low measurement accuracy. Experimental results obtained from thickness measurements on 45 steel ultrasonic test blocks within the range of 3 mm to 20 mm indicate a measurement error of ±0.01 mm, while for thicknesses ranging from 1 mm to 50 mm, the measurement error is ±0.05 mm.

Schlagwörter

Stichwörter der Autor:innen

moving sine fittingmultipliersampling reconstructionultrasonic signal

Autor:innen und Institutionen

  • Hubei Key Laboratory of Modern Manufacturing Quantity Engineering, College of Mechanical Engineering, Hubei University of Technology, Wuhan 430068, China.

ORCID-Profile: Wei Feng

Förderung

  • the National Natural Science Foundation of China
  • Hubei Natural Science Foundation
  • Wuhan Keyresearch and development plan
  • National Natural Science Foundation of China

Zitieren

APA

Gong, W., Wang, X., Yang, Z., Zhai, Z., Feng, W., & Liu, D. (2023). Ultrasonic Thickness Measurement Method and System Implementation Based on Sampling Reconstruction and Phase Feature Extraction. Sensors, 23(22), 9072. https://doi.org/10.3390/s23229072

Vancouver

Gong W, Wang X, Yang Z, Zhai Z, Feng W, Liu D. Ultrasonic Thickness Measurement Method and System Implementation Based on Sampling Reconstruction and Phase Feature Extraction. Sensors. 2023;23(22):9072. doi:10.3390/s23229072

BibTeX
@article{Gong2023,
  author = {Gong, Wenqiang and Wang, Xuanze and Yang, Zhenyu and Zhai, Zhongsheng and Feng, Wei and Liu, Da},
  title = {Ultrasonic Thickness Measurement Method and System Implementation Based on Sampling Reconstruction and Phase Feature Extraction},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {22},
  pages = {9072},
  doi = {10.3390/s23229072}
}
Kostenlos starten →