EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Baseline-Free Damage Imaging of Composite Lap Joint via Parallel Array of Piezoelectric Sensors

Mohsen Barzegar iD, Artur L Ribeiro, Dario J Pasadas iD, Aadhik Asokkumar, Renaldas Raišutis iD, Helena G Ramos iD

Sensors · 08.11.2023 · 23 (22) · 9050

DOI: 10.3390/s23229050 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 08.11.2023. Verfasst von Mohsen Barzegar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Instituto de Telecomunicações, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: GW4SHM - European Union's Horizon 2020 Research and Innovation Program under the Marie Skłodow-ska-Curie, Instituto de Telecomunicações (IT), Portuguese Science and Technology Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a baseline-free damage imaging technique using a parallel array of piezoelectric sensors and a control board that facilitates custom combinations of sensor selection. This technique incorporates an imaging algorithm that uses parallel beams for generation and reception of ultrasonic guided waves in a pitch–catch configuration. A baseline-free reconstruction algorithm for probabilistic inspection of defects (RAPID) algorithm is adopted. The proposed RAPID method replaces the conventional approach of using signal difference coefficients with the maximum signal envelope as a damage index, ensuring independence from baseline data. Additionally, conversely to the conventional RAPID algorithm which uses all possible sensor combinations, an innovative selection of combinations is proposed to mitigate attenuation effects. The proposed method is designed for the inspection of lap joints. Experimental measurements were carried out on a composite lap joint, which featured two dissimilar-sized disbonds positioned at the lap joint’s borderline. A 2D correlation coefficient was used to quantitatively determine the similarity between the obtained images and a reference image with correct defect shapes and locations. The results demonstrate the effectiveness of the proposed damage imaging method in detecting both defects. Additionally, parametric studies were conducted to illustrate how various parameters influence the accuracy of the obtained imaging results.

Schlagwörter

Stichwörter der Autor:innen

baseline-freecomposite lap jointdamage imagingsensor arraystructural health monitoringultrasonic guided waves

Autor:innen und Institutionen

  • Instituto de Telecomunicações, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal.
  • Prof. K. Baršauskas Ultrasound Research Institute, Kaunas University of Technology, 51423 Kaunas, Lithuania.

ORCID-Profile: Mohsen Barzegar, Dario J Pasadas, Renaldas Raišutis, Helena G Ramos

Förderung

  • GW4SHM - European Union's Horizon 2020 Research and Innovation Program under the Marie Skłodow-ska-Curie
  • Instituto de Telecomunicações (IT)
  • Portuguese Science and Technology Foundation

Zitieren

APA

Barzegar, M., Ribeiro, A. L., Pasadas, D. J., Asokkumar, A., Raišutis, R., & Ramos, H. G. (2023). Baseline-Free Damage Imaging of Composite Lap Joint via Parallel Array of Piezoelectric Sensors. Sensors, 23(22), 9050. https://doi.org/10.3390/s23229050

Vancouver

Barzegar M, Ribeiro AL, Pasadas DJ, Asokkumar A, Raišutis R, Ramos HG. Baseline-Free Damage Imaging of Composite Lap Joint via Parallel Array of Piezoelectric Sensors. Sensors. 2023;23(22):9050. doi:10.3390/s23229050

BibTeX
@article{Barzegar2023,
  author = {Barzegar, Mohsen and Ribeiro, Artur L and Pasadas, Dario J and Asokkumar, Aadhik and Raišutis, Renaldas and Ramos, Helena G},
  title = {Baseline-Free Damage Imaging of Composite Lap Joint via Parallel Array of Piezoelectric Sensors},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {22},
  pages = {9050},
  doi = {10.3390/s23229050}
}
Kostenlos starten →