EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique

Soohyeon Rho iD, Hyelim Kim iD, Daeyoung Lim, Wonyoung Jeong iD

Sensors · 2023

DOI: 10.3390/s23219012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Soohyeon Rho und 3 weiteren Autor:innen. Beteiligte Einrichtung: Material and Component Convergence R&D Department, Korea Institute of Industrial Technology (KITECH), Ansan 15588, Republic of Korea. Hauptthemen laut MEDLINE: Textiles, Electricity. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Development of flexible and stretchable conductive thread and sensor device based on X-ray computed tomography observation, Development of microfactory-based technology for future smartwear manufacturing.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable 2.0 research has been conducted on the manufacture of smart fitness wear that collects bio-signals through the wearing of a textile-based electrode. Among them, the electromyography (EMG) suit measures the electrical signals generated by the muscles to check their activity, such as contraction and relaxation. General gel-type electrodes have been reported to cause skin diseases due to an uncomfortable feel and skin irritation when attached to the skin for a long time. Dry electrodes of various materials are being developed to solve this problem. Previous research has reported EMG detectio performance and conducted economic comparisons according to the size and shape of the embroidery electrode. On the other hand, these embroidery electrodes still have foreign body sensations. In this study, a moss sEMG electrode was produced with various shapes (W3 and WF) and loop lengths (1–5 mm). The optimized conditions of the embroidery-based electrodes were derived and analyzed with the tactile comfort factors and sensing performances. As the loop length of the electrode increased, MIU and Qmax increased, but the SMD decreased due to the free movement of the threads constituting the loop. Impedance and sEMG detection performance showed different trends depending on the electrode type.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TextilesElectricityElectromyographyElectric ImpedanceElectrodes

Stichwörter der Autor:innen

electromyographyembroiderysEMG electrodesmart clothingtextile electrode

Autor:innen und Institutionen

  • Material and Component Convergence R&D Department, Korea Institute of Industrial Technology (KITECH), Ansan 15588, Republic of Korea.
  • Department of Nano Science and Technology, Sungkyunkwan University, Suwon 16419, Republic of Korea.

ORCID-Profile: Soohyeon Rho, Hyelim Kim, Wonyoung Jeong

Förderung

  • Development of flexible and stretchable conductive thread and sensor device based on X-ray computed tomography observation
  • Development of microfactory-based technology for future smartwear manufacturing

Zitieren

APA

Rho, S., Kim, H., Lim, D., & Jeong, W. (2023). Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique. Sensors. https://doi.org/10.3390/s23219012

Vancouver

Rho S, Kim H, Lim D, Jeong W. Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique. Sensors. 2023. doi:10.3390/s23219012

BibTeX
@article{Rho2023,
  author = {Rho, Soohyeon and Kim, Hyelim and Lim, Daeyoung and Jeong, Wonyoung},
  title = {Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23219012}
}
Kostenlos starten →