Fachartikel in der Zeitschrift Sensors, online erschienen am 28.01.2023. Verfasst von Tiago Nunes und 1 weiteren Autor:innen. Beteiligte Einrichtung: PLUX Wireless Biosignals, 1050-059 Lisbon, Portugal. Hauptthemen laut MEDLINE: Textiles, Wearable Electronic Devices. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union.
Abstract (Originalsprache)
When long-term biosignal monitoring is required via surface electrodes, the use of conventional silver/silver chloride (Ag/AgCl) gelled electrodes may not be the best solution, as the gel in the electrodes tends to dry out over time. In this work, the electrical behaviour and performance of dry electrodes for biopotential monitoring was assessed. Three materials were investigated and compared against the gold-standard Ag/AgCl gelled electrodes. To characterize their electrical behaviour, the impedance response over the frequency was evaluated, as well as its signal to noise ratio. The electrodes’ performance was evaluated by integrating them in a proven electrocardiogram (ECG) acquisition setup where an ECG signal was acquired simultaneously with a set of dry electrodes and a set of standard Ag/AgCl gelled electrodes as reference. The obtained results were morphologically compared using the Normalised Root Mean Squared Error (nRMSE) and the Cosine Similarity (CS). The findings of this work suggest that the use of dry electrodes for biopotential monitoring is a suitable replacement for the conventional Ag/AgCl gelled electrodes. The signal obtained with dry electrodes is comparable to the one obtained with the gold standard, with the advantage that these do not require the use of gel and can be easily integrated into fabric to facilitate their use in long-term monitoring scenarios.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- PLUX Wireless Biosignals, 1050-059 Lisbon, Portugal.
- NOVA School of Science and Technology, NOVA University of Lisbon, 2829-516 Caparica, Portugal.
- Instituto de Telecomunicações, 1049-001 Lisboa, Portugal.
ORCID-Profile: Tiago Nunes, Hugo Plácido da Silva
Förderung
- European Union
Zitieren
APA
Nunes, T., & da Silva, H. P. (2023). Characterization and Validation of Flexible Dry Electrodes for Wearable Integration. Sensors, 23(3), 1468. https://doi.org/10.3390/s23031468
Vancouver
Nunes T, da Silva HP. Characterization and Validation of Flexible Dry Electrodes for Wearable Integration. Sensors. 2023;23(3):1468. doi:10.3390/s23031468
BibTeX
@article{Nunes2023,
author = {Nunes, Tiago and da Silva, Hugo Plácido},
title = {Characterization and Validation of Flexible Dry Electrodes for Wearable Integration},
journal = {Sensors},
year = {2023},
volume = {23},
number = {3},
pages = {1468},
doi = {10.3390/s23031468}
}
EUVIMED