Effect of Robotic-Assisted Gait at Different Levels of Guidance and Body Weight Support on Lower Limb Joint Kinematics and Coordination
Sensors · 2023
DOI: 10.3390/s23218800 ↗At a glance
Journal article in Sensors, 2023. Written by Yosra Cherni and 4 co-authors. Institution: Laboratoire de Simulation et Modélisation du Mouvement, École de Kinésiologie et des Sciences de l'Activité Physique, Université de Montréal, Montréa…. Major MEDLINE topics: Robotic Surgical Procedures. Cited 4 times so far (Crossref); 49 references. The full text is freely available (open access, CC BY 4.0). Funded by: FRQS, GRSTB, NSERC.
Abstract (original language)
The Lokomat provides task-oriented therapy for patients with gait disorders. This robotic technology drives the lower limbs in the sagittal plane. However, normative gait also involves motions in the coronal and transverse planes. This study aimed to compare the Lokomat with Treadmill gait through three-dimensional (3D)-joint kinematics and inter-joint coordination. Lower limb kinematics was recorded in 18 healthy participants who walked at 3 km/h on a Treadmill or in a Lokomat with nine combinations of Guidance (30%, 50%, 70%) and bodyweight support (30%, 50%, 70%). Compared to the Treadmill, the Lokomat altered pelvic rotation, decreased pelvis obliquity and hip adduction, and increased ankle rotation. Moreover, the Lokomat resulted in significantly slower velocity at the hip, knee, and ankle flexion compared to the treadmill condition. Moderate to strong correlations were observed between the Treadmill and Lokomat conditions in terms of inter-joint coordination between hip–knee (r = 0.67–0.91), hip–ankle (r = 0.66–0.85), and knee–ankle (r = 0.90–0.95). This study showed that some gait determinants, such as pelvis obliquity, rotation, and hip adduction, are altered when walking with Lokomat in comparison to a Treadmill. Kinematic deviations induced by the Lokomat were most prominent at high levels of bodyweight support. Interestingly, different levels of Guidance did not affect gait kinematics. The present results can help therapists to adequately select settings during Lokomat therapy.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Laboratoire de Simulation et Modélisation du Mouvement, École de Kinésiologie et des Sciences de l'Activité Physique, Université de Montréal, Montréal, QC H3T 1J4, Canada.
- Centre de Recherche du CHU Ste Justine, Montréal, QC H3T 1C5, Canada.
- Centre de Recherche et d'Innovation Sur le Sport, Université de Lyon, 69007 Lyon, France.
- Département des Sciences de l'Activité Physique, Université du Québec à Montréal, Montréal, QC H2L 2C4, Canada.
- Centre Interdisciplinaire sur le Cerveau et l'Apprentissage, Université de Montréal, Montréal, QC H3C 3J7, Canada.
ORCID profiles: Yosra Cherni, Mickael Begon, Laurent Ballaz
Funding
- FRQS
- GRSTB
- NSERC
Cite
APA
Cherni, Y., Blache, Y., Begon, M., Ballaz, L., & Dal Maso, F. (2023). Effect of Robotic-Assisted Gait at Different Levels of Guidance and Body Weight Support on Lower Limb Joint Kinematics and Coordination. Sensors. https://doi.org/10.3390/s23218800
Vancouver
Cherni Y, Blache Y, Begon M, Ballaz L, Dal Maso F. Effect of Robotic-Assisted Gait at Different Levels of Guidance and Body Weight Support on Lower Limb Joint Kinematics and Coordination. Sensors. 2023. doi:10.3390/s23218800
BibTeX
@article{Cherni2023,
author = {Cherni, Yosra and Blache, Yoann and Begon, Mickael and Ballaz, Laurent and Dal Maso, Fabien},
title = {Effect of Robotic-Assisted Gait at Different Levels of Guidance and Body Weight Support on Lower Limb Joint Kinematics and Coordination},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23218800}
}
EUVIMED