Sensitivity of Model-Based Predictions of Post-TKA Kinematic Behavior to Residual Errors in Ultrasound-Based Knee Collateral Ligament Strain Assessment
Sensors · 2023
DOI: 10.3390/s23198268 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Félix Dandois und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Orthopaedic Research and Training (IORT), Development and Regeneration Department, KU Leuven, 49 Herestraat, 3000 Leuven, Belgium. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Collateral Ligaments, Knee Injuries. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: KU Leuven Interdisciplinary Network (ID-N) funding program.
Abstract (Originalsprache)
Ultrasound-based ligament strain estimation shows promise in non-invasively assessing knee joint collateral ligament behavior and improving ligament balancing procedures. However, the impact of ultrasound-based strain estimation residual errors on in-silico arthroplasty predictions remains unexplored. We investigated the sensitivity of post-arthroplasty kinematic predictions to ultrasound-based strain estimation errors compared to clinical inaccuracies in implant positioning.Two cadaveric legs were submitted to active squatting, and specimen-specific rigid computer models were formulated. Mechanical properties of the ligament model were optimized to reproduce experimentally obtained tibiofemoral kinematics and loads with minimal error. Resulting remaining errors were comparable to the current state-of-the-art. Ultrasound-derived strain residual errors were then introduced by perturbing lateral collateral ligament (LCL) and medial collateral ligament (MCL) stiffness. Afterwards, the implant position was perturbed to match with the current clinical inaccuracies reported in the literature. Finally, the impact on simulated post-arthroplasty tibiofemoral kinematics was compared for both perturbation scenarios. Ultrasound-based errors minimally affected kinematic outcomes (mean differences < 0.73° in rotations, 0.1 mm in translations). Greatest differences occurred in external tibial rotations (−0.61° to 0.73° for MCL, −0.28° to 0.27° for LCL). Comparatively, changes in implant position had larger effects, with mean differences up to 1.95° in external tibial rotation and 0.7 mm in mediolateral translation. In conclusion, our study demonstrated that the ultrasound-based assessment of collateral ligament strains has the potential to enhance current computer-based pre-operative knee arthroplasty planning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute for Orthopaedic Research and Training (IORT), Development and Regeneration Department, KU Leuven, 49 Herestraat, 3000 Leuven, Belgium.
- ReSurg SA, Rue Saint-Jean 22, 1260 Nyon, Switzerland.
- Department of Orthopaedics, University Hospitals Leuven, 49 Herestraat, 3000 Leuven, Belgium.
ORCID-Profile: Félix Dandois
Förderung
- KU Leuven Interdisciplinary Network (ID-N) funding program
Zitieren
APA
Dandois, F., Taylan, O., Müller, J. H., & Scheys, L. (2023). Sensitivity of Model-Based Predictions of Post-TKA Kinematic Behavior to Residual Errors in Ultrasound-Based Knee Collateral Ligament Strain Assessment. Sensors. https://doi.org/10.3390/s23198268
Vancouver
Dandois F, Taylan O, Müller JH, Scheys L. Sensitivity of Model-Based Predictions of Post-TKA Kinematic Behavior to Residual Errors in Ultrasound-Based Knee Collateral Ligament Strain Assessment. Sensors. 2023. doi:10.3390/s23198268
BibTeX
@article{Dandois2023,
author = {Dandois, Félix and Taylan, Orçun and Müller, Jacobus H and Scheys, Lennart},
title = {Sensitivity of Model-Based Predictions of Post-TKA Kinematic Behavior to Residual Errors in Ultrasound-Based Knee Collateral Ligament Strain Assessment},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23198268}
}
EUVIMED