EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Sensitivity of Model-Based Predictions of Post-TKA Kinematic Behavior to Residual Errors in Ultrasound-Based Knee Collateral Ligament Strain Assessment

Félix Dandois iD, Orçun Taylan, Jacobus H Müller, Lennart Scheys

Sensors · 2023

DOI: 10.3390/s23198268 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Félix Dandois und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Orthopaedic Research and Training (IORT), Development and Regeneration Department, KU Leuven, 49 Herestraat, 3000 Leuven, Belgium. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Collateral Ligaments, Knee Injuries. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: KU Leuven Interdisciplinary Network (ID-N) funding program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasound-based ligament strain estimation shows promise in non-invasively assessing knee joint collateral ligament behavior and improving ligament balancing procedures. However, the impact of ultrasound-based strain estimation residual errors on in-silico arthroplasty predictions remains unexplored. We investigated the sensitivity of post-arthroplasty kinematic predictions to ultrasound-based strain estimation errors compared to clinical inaccuracies in implant positioning.Two cadaveric legs were submitted to active squatting, and specimen-specific rigid computer models were formulated. Mechanical properties of the ligament model were optimized to reproduce experimentally obtained tibiofemoral kinematics and loads with minimal error. Resulting remaining errors were comparable to the current state-of-the-art. Ultrasound-derived strain residual errors were then introduced by perturbing lateral collateral ligament (LCL) and medial collateral ligament (MCL) stiffness. Afterwards, the implant position was perturbed to match with the current clinical inaccuracies reported in the literature. Finally, the impact on simulated post-arthroplasty tibiofemoral kinematics was compared for both perturbation scenarios. Ultrasound-based errors minimally affected kinematic outcomes (mean differences < 0.73° in rotations, 0.1 mm in translations). Greatest differences occurred in external tibial rotations (−0.61° to 0.73° for MCL, −0.28° to 0.27° for LCL). Comparatively, changes in implant position had larger effects, with mean differences up to 1.95° in external tibial rotation and 0.7 mm in mediolateral translation. In conclusion, our study demonstrated that the ultrasound-based assessment of collateral ligament strains has the potential to enhance current computer-based pre-operative knee arthroplasty planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeCollateral LigamentsKnee InjuriesHumansBiomechanical PhenomenaKnee JointTibiaRange of Motion, ArticularCadaver

Stichwörter der Autor:innen

collateral ligamentsknee arthroplastymodelingstrainsultrasound

Autor:innen und Institutionen

  • Institute for Orthopaedic Research and Training (IORT), Development and Regeneration Department, KU Leuven, 49 Herestraat, 3000 Leuven, Belgium.
  • ReSurg SA, Rue Saint-Jean 22, 1260 Nyon, Switzerland.
  • Department of Orthopaedics, University Hospitals Leuven, 49 Herestraat, 3000 Leuven, Belgium.

ORCID-Profile: Félix Dandois

Förderung

  • KU Leuven Interdisciplinary Network (ID-N) funding program

Zitieren

APA

Dandois, F., Taylan, O., Müller, J. H., & Scheys, L. (2023). Sensitivity of Model-Based Predictions of Post-TKA Kinematic Behavior to Residual Errors in Ultrasound-Based Knee Collateral Ligament Strain Assessment. Sensors. https://doi.org/10.3390/s23198268

Vancouver

Dandois F, Taylan O, Müller JH, Scheys L. Sensitivity of Model-Based Predictions of Post-TKA Kinematic Behavior to Residual Errors in Ultrasound-Based Knee Collateral Ligament Strain Assessment. Sensors. 2023. doi:10.3390/s23198268

BibTeX
@article{Dandois2023,
  author = {Dandois, Félix and Taylan, Orçun and Müller, Jacobus H and Scheys, Lennart},
  title = {Sensitivity of Model-Based Predictions of Post-TKA Kinematic Behavior to Residual Errors in Ultrasound-Based Knee Collateral Ligament Strain Assessment},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23198268}
}
Kostenlos starten →