Systematische Übersicht in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 26.02.2025. Verfasst von Roland Becker und 7 weiteren Autor:innen. Beteiligte Einrichtung: Center of Orthopaedics and Traumatology, Brandenburg Medical School, University Hospital Brandenburg an der Havel, Brandenburg an der Havel, Germany. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Joint, Collateral Ligaments. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 168 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Proper tension of the collateral ligaments is the key to success in total knee arthroplasty (TKA). The study aimed to identify the distraction force for the medial and lateral femorotibial compartments in tension‐controlled ligament‐balanced TKA at 0° and 90° of knee flexion.

Methods

A literature search was conducted in PubMed up to 31 December 2024 to identify studies that reported exact values of the distraction force applied in tension‐controlled ligament‐balanced TKA. Mean distraction force at 0° and 90° of knee flexion were calculated for the native knee, cadaver knee, and computer model/artificial knee groups. Differences between groups were calculated using Kruskal–Wallis and Mann–Whitney U tests, with p ≤ 0.05 considered significant. A frequentist meta‐analysis of subgroup analysis between native and cadaver knee studies was performed using a random effects model with inverse variance and the Sidik–Jonkman heterogeneity estimator with Hartung–Knapp adjustment to calculate participant age and sex.

Results

Out of 116 included primary studies involved, a total of 6869 participants had distraction force measurements during TKA. The mean distraction force was 149.9 N (35.0–320.0 N) at 0° knee extension and 139.5 N (14.7–244.7 N) at 90° of flexion. Using the Kruskal–Wallis test or the Mann–Whitney U test, there were no significant differences in distraction force between native knee, cadaver knee, computer model/artificial knee studies at extension ( p = 0.2480 and p = 0.1130) and at 90° of knee flexion ( p = 0.8439 and p = 0.6241).

Conclusion

This meta‐analysis is the first to quantify distraction force in TKA, providing essential reference values of 149.9 N at 0° extension and 139.5 N at 90° flexion. These findings offer valuable guidelines for intraoperative soft tissue management during TKA procedures. The consistency of distraction force across different experimental models suggests that these values are broadly applicable. However, it remains unclear whether a more personalized distraction force should be considered for gap preparation. Level of Evidence Level IV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee JointCollateral LigamentsHumansBiomechanical PhenomenaRange of Motion, ArticularCadaver

Stichwörter der Autor:innen

distraction forceligament tensionreplacementtotal knee arthroplasty

Autor:innen und Institutionen

  • Center of Orthopaedics and Traumatology, Brandenburg Medical School, University Hospital Brandenburg an der Havel, Brandenburg an der Havel, Germany.
  • Faculty of Health Science Brandenburg, Brandenburg Medical School Theodor Fontane, Brandenburg an der Havel, Germany.
  • Faculty of Applied Computer Science, Deggendorf Institute of Technology, Deggendorf, Germany.
  • Istanbul Fatih Sultan Mehmet Training and Research Hospital, University of Health Sciences, Istanbul, Turkey.
  • Ortoklinik & Çankaya Hospital, Ankara, Turkey.
  • Department Orthopaedic Surgery, Südtiroler Sanitätsbetrieb, Brixen, Italy.

Zitieren

APA

Becker, R., Voss, M., Lettner, J., Hable, R., Kayaalp, M. E., Tandogan, R., Indelli, P., & Ramadanov, N. (2025). Mean distraction force applied in tension‐controlled ligament‐balanced total knee arthroplasty: A systematic review and meta‐analysis. Knee Surgery, Sports Traumatology, Arthroscopy, 33(7), 2498-2526. https://doi.org/10.1002/ksa.12629

Vancouver

Becker R, Voss M, Lettner J, Hable R, Kayaalp ME, Tandogan R, et al. Mean distraction force applied in tension‐controlled ligament‐balanced total knee arthroplasty: A systematic review and meta‐analysis. Knee Surgery, Sports Traumatology, Arthroscopy. 2025;33(7):2498-2526. doi:10.1002/ksa.12629

BibTeX
@article{Becker2025,
  author = {Becker, Roland and Voss, Maximilan and Lettner, Jonathan and Hable, Robert and Kayaalp, Mahmut Enes and Tandogan, Reha and Indelli, Pier and Ramadanov, Nikolai},
  title = {Mean distraction force applied in tension‐controlled ligament‐balanced total knee arthroplasty: A systematic review and meta‐analysis},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  volume = {33},
  number = {7},
  pages = {2498--2526},
  doi = {10.1002/ksa.12629}
}
Kostenlos starten →