EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A webcam-based machine learning approach for three-dimensional range of motion evaluation

Xiaoye Michael Wang iD, Derek T Smith, Qin Zhu

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0293178 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Xiaoye Michael Wang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, ON, Canada. Hauptthemen laut MEDLINE: Arthrometry, Articular, Shoulder. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIMHD NIH HHS, National Institute on Minority Health and Health Disparities, US Department of the Treasure and Wyoming Health & Bioscience Innovation Hub.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Joint range of motion (ROM) is an important quantitative measure for physical therapy. Commonly relying on a goniometer, accurate and reliable ROM measurement requires extensive training and practice. This, in turn, imposes a significant barrier for those who have limited in-person access to healthcare.

Objective

The current study presents and evaluates an alternative machine learning-based ROM evaluation method that could be remotely accessed via a webcam.

Methods

To evaluate its reliability, the ROM measurements for a diverse set of joints (neck, spine, and upper and lower extremities) derived using this method were compared to those obtained from a marker-based optical motion capture system.

Results

Data collected from 25 healthy adults demonstrated that the webcam solution exhibited high test-retest reliability, with substantial to almost perfect intraclass correlation coefficients for most joints. Compared with the marker-based system, the webcam-based system demonstrated substantial to almost perfect inter-rater reliability for some joints, and lower inter-rater reliability for other joints (e.g., shoulder flexion and elbow flexion), which could be attributed to the reduced sensitivity to joint locations at the apex of the movement.

Conclusions

The proposed webcam-based method exhibited high test-retest and inter-rater reliability, making it a versatile alternative for existing ROM evaluation methods in clinical practice and the tele-implementation of physical therapy and rehabilitation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthrometry, ArticularShoulderAdultHumansReproducibility of ResultsRange of Motion, ArticularUpper Extremity

Autor:innen und Institutionen

  • Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, ON, Canada.
  • Division of Kinesiology and Health, University of Wyoming, Laramie, WY, United States of America.

ORCID-Profile: Xiaoye Michael Wang

Förderung

  • NIMHD NIH HHS
  • National Institute on Minority Health and Health Disparities
  • US Department of the Treasure and Wyoming Health & Bioscience Innovation Hub

Zitieren

APA

Wang, X. M., Smith, D. T., & Zhu, Q. (2023). A webcam-based machine learning approach for three-dimensional range of motion evaluation. PLOS ONE. https://doi.org/10.1371/journal.pone.0293178

Vancouver

Wang XM, Smith DT, Zhu Q. A webcam-based machine learning approach for three-dimensional range of motion evaluation. PLOS ONE. 2023. doi:10.1371/journal.pone.0293178

BibTeX
@article{Wang2023,
  author = {Wang, Xiaoye Michael and Smith, Derek T and Zhu, Qin},
  title = {A webcam-based machine learning approach for three-dimensional range of motion evaluation},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0293178}
}
Kostenlos starten →