A Liquid Crystal-Modulated Metastructure Sensor for Biosensing
Sensors · 11.08.2023 · 23 (16) · 7122
DOI: 10.3390/s23167122 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 11.08.2023. Verfasst von Siyuan Liao und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology), Nanjing University of Posts and Telecommunicatio…. Hauptthemen laut MEDLINE: Liquid Crystals. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National College Student Innovation Training Program, College Student Innovation Training Program of Nanjing University of Posts and Telecommunications.
Abstract (Originalsprache)
In this paper, a liquid crystal-modulated metastructure sensor (MS) is proposed that can detect the refractive index (RI) of a liquid and change the detection range under different applied voltages. The regulation of the detection range is based on the different bias states of the liquid crystal at different voltages. By changing the sample in the cavity that is to be detected, the overall electromagnetic characteristics of the device in the resonant state are modified, thus changing the position of the absorption peaks so that different RI correspond to different absorption peaks, and finally realizing the sensing detection. The refractive index unit is denoted as RIU. The range of the refractive index detection is 1.414–2.828 and 2.121–3.464, and the corresponding absorption peak variation range is 0.8485–1.028 THz and 0.7295–0.8328 THz, with a sensitivity of 123.8 GHz/RIU and 75.6 GHz/RIU, respectively. In addition, an approach to optimizing resonant absorption peaks is explored, which can suppress unwanted absorption generated during the design process by analyzing the energy distribution and directing the current flow on the substrate. Four variables that have a more obvious impact on performance are listed, and the selection and change trend of the numerical values are focused on, fully considering the errors that may be caused by manufacturing and actual use. At the same time, the incident angle and polarization angle are also included in the considered range, and the device shows good stability at these angles. Finally, the influence of the number of resonant rings on the sensing performance is also discussed, and its conclusion has guiding value for optimizing the sensing demand. This new liquid crystal-modulated MS has the advantages of a small size and high sensitivity and is expected to be used for bio-detection, sensing, and so on. All results in this work were obtained with the aid of simulations based on the finite element method.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology), Nanjing University of Posts and Telecommunications, Nanjing 210023, China.
ORCID-Profile: Siyuan Liao, Haifeng Zhang
Förderung
- National College Student Innovation Training Program
- College Student Innovation Training Program of Nanjing University of Posts and Telecommunications
Zitieren
APA
Liao, S., Chen, Q., Ma, H., Huang, J., Sui, J., & Zhang, H. (2023). A Liquid Crystal-Modulated Metastructure Sensor for Biosensing. Sensors, 23(16), 7122. https://doi.org/10.3390/s23167122
Vancouver
Liao S, Chen Q, Ma H, Huang J, Sui J, Zhang H. A Liquid Crystal-Modulated Metastructure Sensor for Biosensing. Sensors. 2023;23(16):7122. doi:10.3390/s23167122
BibTeX
@article{Liao2023,
author = {Liao, Siyuan and Chen, Qi and Ma, Haocheng and Huang, Jingwei and Sui, Junyang and Zhang, Haifeng},
title = {A Liquid Crystal-Modulated Metastructure Sensor for Biosensing},
journal = {Sensors},
year = {2023},
volume = {23},
number = {16},
pages = {7122},
doi = {10.3390/s23167122}
}
EUVIMED