Drift-Free Joint Angle Calculation Using Inertial Measurement Units without Magnetometers: An Exploration of Sensor Fusion Methods for the Elbow and Wrist
Sensors · 2023
DOI: 10.3390/s23167053 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Howard Chen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Industrial & Systems Engineering and Engineering Management Department, University of Alabama in Huntsville, Huntsville, AL 35899, USA. Hauptthemen laut MEDLINE: Elbow, Elbow Joint. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIOSH CDC HHS, Heartland Center for Occupational Health and Safety at the University of Iowa, Deep South Center for Occupational Health and Safety at the University of Alabama-Birmingham (UAB) and Auburn University.
Abstract (Originalsprache)
Joint angles of the lower extremities have been calculated using gyroscope and accelerometer measurements from inertial measurement units (IMUs) without sensor drift by leveraging kinematic constraints. However, it is unknown whether these methods are generalizable to the upper extremity due to differences in motion dynamics. Furthermore, the extent that post-processed sensor fusion algorithms can improve measurement accuracy relative to more commonly used Kalman filter-based methods remains unknown. This study calculated the elbow and wrist joint angles of 13 participants performing a simple ≥30 min material transfer task at three rates (slow, medium, fast) using IMUs and kinematic constraints. The best-performing sensor fusion algorithm produced total root mean square errors (i.e., encompassing all three motion planes) of 6.6°, 3.6°, and 2.0° for the slow, medium, and fast transfer rates for the elbow and 2.2°, 1.7°, and 1.5° for the wrist, respectively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Industrial & Systems Engineering and Engineering Management Department, University of Alabama in Huntsville, Huntsville, AL 35899, USA.
- Department of Industrial & Systems Engineering, Auburn University, Auburn, AL 36849, USA.
- Department of Mechanical Engineering, Auburn University, Auburn, AL 36849, USA.
- Department of Occupational & Environmental Health, The University of Iowa, Iowa City, IA 52242, USA.
ORCID-Profile: Howard Chen, Mark C Schall
Förderung
- NIOSH CDC HHS
- Heartland Center for Occupational Health and Safety at the University of Iowa
- Deep South Center for Occupational Health and Safety at the University of Alabama-Birmingham (UAB) and Auburn University
Zitieren
APA
Chen, H., Schall, M. C., Martin, S. M., & Fethke, N. B. (2023). Drift-Free Joint Angle Calculation Using Inertial Measurement Units without Magnetometers: An Exploration of Sensor Fusion Methods for the Elbow and Wrist. Sensors. https://doi.org/10.3390/s23167053
Vancouver
Chen H, Schall MC, Martin SM, Fethke NB. Drift-Free Joint Angle Calculation Using Inertial Measurement Units without Magnetometers: An Exploration of Sensor Fusion Methods for the Elbow and Wrist. Sensors. 2023. doi:10.3390/s23167053
BibTeX
@article{Chen2023,
author = {Chen, Howard and Schall, Mark C and Martin, Scott M and Fethke, Nathan B},
title = {Drift-Free Joint Angle Calculation Using Inertial Measurement Units without Magnetometers: An Exploration of Sensor Fusion Methods for the Elbow and Wrist},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23167053}
}
EUVIMED