EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessment of Passive Upper Limb Stiffness and Its Function in Post-Stroke Individuals Wearing an Inertial Sensor during the Pendulum Test

Milene Soares Nogueira de Lima iD, Clarissa Cardoso Dos Santos Couto Paz, Thais Gontijo Ribeiro, Emerson Fachin-Martins iD

Sensors · 2023

DOI: 10.3390/s23073487 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Milene Soares Nogueira de Lima und 3 weiteren Autor:innen. Beteiligte Einrichtung: Program in Health Sciences and Technologies, Faculdade de Ceilândia, Universidade de Brasília, Brasília 70910-900, Brazil. Hauptthemen laut MEDLINE: Stroke, Stroke Rehabilitation, Elbow Joint. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES), Decanato de Pesquisa e Inovação e de Pós-Graduação, Fundação de Apoio à Pesquisa do Distrito Federal.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article proposes the evaluation of the passive movement of the affected elbow during the pendulum test in people with stroke and its correlation with the main clinical scales (Modified Ashworth Scale, Motor Activity Log, and Fulg Meyer). An inertial sensor was attached to the forearm of seven subjects, who then passively flexed and extended the elbow. Joint angles and variables that indicate viscoelastic properties, stiffness (K), damping (B), E1 amp, F1 amp, and relaxation indices were collected. The results show that the FM scale is significantly correlated with the natural frequency (p = 0.024). The MAL amount-of-use score correlates with the natural frequency (p = 0.024). The variables E1 amp, F1 amp, RI, and ERI are not correlated with the clinical scales, but they correlate with each other; the variable E1 amp correlates with F1 amp (p = 0.024) and RI (p = 0.024), while F1 amp correlates with ERI (p = 0.024). There was also a correlation between the natural frequency and K (r = 0.96, p = 0.003). Non-linear results were found for the properties of the elbow joint during the pendulum test, which may be due to the presence of neural and non-neural factors. These results may serve as a reference for future studies if alternative scales do not provide an accurate reflection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StrokeStroke RehabilitationElbow JointHumansUpper ExtremityElbow

Stichwörter der Autor:innen

inertial sensorspasticitystiffnessstrokethe pendulum testupper limb

Autor:innen und Institutionen

  • Program in Health Sciences and Technologies, Faculdade de Ceilândia, Universidade de Brasília, Brasília 70910-900, Brazil.
  • Course of Physiotherapy, Faculdade de Ceilândia, Universidade de Brasília, Brasília 70719-080, Brazil.
  • Secretaria de Saúde do Distrito Federal, Brasília 72445-020, Brazil.

ORCID-Profile: Milene Soares Nogueira de Lima, Emerson Fachin-Martins

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES)
  • Decanato de Pesquisa e Inovação e de Pós-Graduação
  • Fundação de Apoio à Pesquisa do Distrito Federal

Zitieren

APA

de Lima, M. S. N., Dos Santos Couto Paz, C. C., Ribeiro, T. G., & Fachin-Martins, E. (2023). Assessment of Passive Upper Limb Stiffness and Its Function in Post-Stroke Individuals Wearing an Inertial Sensor during the Pendulum Test. Sensors. https://doi.org/10.3390/s23073487

Vancouver

de Lima MSN, Dos Santos Couto Paz CC, Ribeiro TG, Fachin-Martins E. Assessment of Passive Upper Limb Stiffness and Its Function in Post-Stroke Individuals Wearing an Inertial Sensor during the Pendulum Test. Sensors. 2023. doi:10.3390/s23073487

BibTeX
@article{deLima2023,
  author = {de Lima, Milene Soares Nogueira and Dos Santos Couto Paz, Clarissa Cardoso and Ribeiro, Thais Gontijo and Fachin-Martins, Emerson},
  title = {Assessment of Passive Upper Limb Stiffness and Its Function in Post-Stroke Individuals Wearing an Inertial Sensor during the Pendulum Test},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23073487}
}
Kostenlos starten →