Mitigating Under-Sampling Artifacts in 3D Photoacoustic Imaging Using Res-UNet Based on Digital Breast Phantom
Sensors · 2023
DOI: 10.3390/s23156970 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Haoming Huo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Beijing National Research Center for Information Science and Technology, Department of Electronic Engineering, Tsinghua University, Beijing 100084, C…. Hauptthemen laut MEDLINE: Photoacoustic Techniques, Breast Neoplasms. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tsinghua University, the National Science Foundation of China, Tsinghua University Initiative Scientific Research Program.
Abstract (Originalsprache)
In recent years, photoacoustic (PA) imaging has rapidly grown as a non-invasive screening technique for breast cancer detection using three-dimensional (3D) hemispherical arrays due to their large field of view. However, the development of breast imaging systems is hindered by a lack of patients and ground truth samples, as well as under-sampling problems caused by high costs. Most research related to solving these problems in the PA field were based on 2D transducer arrays or simple regular shape phantoms for 3D transducer arrays or images from other modalities. Therefore, we demonstrate an effective method for removing under-sampling artifacts based on deep neural network (DNN) to reconstruct high-quality PA images using numerical digital breast simulations. We constructed 3D digital breast phantoms based on human anatomical structures and physical properties, which were then subjected to 3D Monte-Carlo and K-wave acoustic simulations to mimic acoustic propagation for hemispherical transducer arrays. Finally, we applied a 3D delay-and-sum reconstruction algorithm and a Res-UNet network to achieve higher resolution on sparsely-sampled data. Our results indicate that when using a 757 nm laser with uniform intensity distribution illuminated on a numerical digital breast, the imaging depth can reach 3 cm with 0.25 mm spatial resolution. In addition, the proposed DNN can significantly enhance image quality by up to 78.4%, as measured by MS-SSIM, and reduce background artifacts by up to 19.0%, as measured by PSNR, even at an under-sampling ratio of 10%. The post-processing time for these improvements is only 0.6 s. This paper suggests a new 3D real time DNN method addressing the sparse sampling problem based on numerical digital breast simulations, this approach can also be applied to clinical data and accelerate the development of 3D photoacoustic hemispherical transducer arrays for early breast cancer diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Beijing National Research Center for Information Science and Technology, Department of Electronic Engineering, Tsinghua University, Beijing 100084, China.
- Institute for Precision Healthcare, Tsinghua University, Beijing 100084, China.
- Institute for Intelligent Healthcare, Tsinghua University, Beijing 100084, China.
Förderung
- Tsinghua University
- the National Science Foundation of China
- Tsinghua University Initiative Scientific Research Program
- National Science Foundation of China
- Initiative Scientific Research Program of Institute for Intelligent Healthcare of Tsinghua University
- Innovation Project of Tsinghua-Foshan Institute of Advanced Manufacturing
Zitieren
APA
Huo, H., Deng, H., Gao, J., Duan, H., & Ma, C. (2023). Mitigating Under-Sampling Artifacts in 3D Photoacoustic Imaging Using Res-UNet Based on Digital Breast Phantom. Sensors. https://doi.org/10.3390/s23156970
Vancouver
Huo H, Deng H, Gao J, Duan H, Ma C. Mitigating Under-Sampling Artifacts in 3D Photoacoustic Imaging Using Res-UNet Based on Digital Breast Phantom. Sensors. 2023. doi:10.3390/s23156970
BibTeX
@article{Huo2023,
author = {Huo, Haoming and Deng, Handi and Gao, Jianpan and Duan, Hanqing and Ma, Cheng},
title = {Mitigating Under-Sampling Artifacts in 3D Photoacoustic Imaging Using Res-UNet Based on Digital Breast Phantom},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23156970}
}