An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts
Sensors · 20.07.2023 · 23 (14) · 6537
DOI: 10.3390/s23146537 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 20.07.2023. Verfasst von Niall Holmes und 3 weiteren Autor:innen. Beteiligte Einrichtung: Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, Wellcome Trust, NIH HHS.
Abstract (Originalsprache)
The signal space separation (SSS) method is routinely employed in the analysis of multichannel magnetic field recordings (such as magnetoencephalography (MEG) data). In the SSS method, signal vectors are posed as a multipole expansion of the magnetic field, allowing contributions from sources internal and external to a sensor array to be separated via computation of the pseudo-inverse of a matrix of the basis vectors. Although powerful, the standard implementation of the SSS method on MEG systems based on optically pumped magnetometers (OPMs) is unstable due to the approximate parity of the required number of dimensions of the SSS basis and the number of channels in the data. Here we exploit the hierarchical nature of the multipole expansion to perform a stable, iterative implementation of the SSS method. We describe the method and investigate its performance via a simulation study on a 192-channel OPM-MEG helmet. We assess performance for different levels of truncation of the SSS basis and a varying number of iterations. Results show that the iterative method provides stable performance, with a clear separation of internal and external sources.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.
- Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK.
- Department of Physics, University of Washington, Seattle, WA 98195, USA.
- Institute for Learning and Brain Sciences, University of Washington, Seattle, WA 98195, USA.
ORCID-Profile: Niall Holmes, Samu Taulu
Förderung
- NIBIB NIH HHS
- Wellcome Trust
- NIH HHS
- UK Engineering and Physical Sciences Research Council (EPSRC)
- National Institutes of Health grant
- National Institutes of Health
- Bezos Family Foundation
- R. B. and Ruth H. Dunn Charitable Foundation
Zitieren
APA
Holmes, N., Bowtell, R., Brookes, M. J., & Taulu, S. (2023). An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts. Sensors, 23(14), 6537. https://doi.org/10.3390/s23146537
Vancouver
Holmes N, Bowtell R, Brookes MJ, Taulu S. An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts. Sensors. 2023;23(14):6537. doi:10.3390/s23146537
BibTeX
@article{Holmes2023,
author = {Holmes, Niall and Bowtell, Richard and Brookes, Matthew J and Taulu, Samu},
title = {An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts},
journal = {Sensors},
year = {2023},
volume = {23},
number = {14},
pages = {6537},
doi = {10.3390/s23146537}
}
EUVIMED