Purpose

Magnetoencephalography is the recording of magnetic fields resulting from the activities of brain neurons and provides the possibility of direct measurement of their activity in a non-invasive manner. Despite its high spatial and temporal resolution, magnetoencephalography has a weak amplitude signal, drastically reducing the signal-to-noise ratio in case of environmental noise. Therefore, signal reconstruction methods can be effective in recovering noisy and lost information. Materials and Methods: The magnetoencephalography signal of 11 healthy young subjects was recorded in a resting state. Each signal contains the data of 148 channels which were fixed on a helmet. The performance of three different reconstruction methods has been investigated by using the data of adjacent channels from the selected track to interpolate its information. These three methods are the surface reconstruction methods, partial differential equations algorithms, and finite element-based methods. Afterward to evaluate the performance of each method, R-square, root mean square error, and signal-to-noise ratio between the reconstructed signal and the original signal were calculated. The relation between these criteria was checked through proper statistical tests with a significance level of 0.05.

Results

The mean method with the root mean square error of 0.016 ± 0.009 (mean ± SD) at the minimum time (3.5 microseconds) could reconstruct an epoch. Also, the median method with a similar error but in 5.9 microseconds with a probability of 99.33% could reconstruct an epoch with an R-square greater than 0.7.

Conclusion

The mean and median methods can reconstruct the noisy or lost signal in magnetoencephalography with a suitable percentage of similarity to the reference by using the signal of adjacent channels from the damaged sensor.

Zitieren

APA

Arabian, H., Karimian, A., Marateb, H. R., Migliorelli, C., Mañanas, M. A., Romero, S., Russi, A., & Nowak, R. (2026). An Effective Method to Repair Poor Signal of Magnetoencephalography Channel Data. Frontiers in Biomedical Technologies. https://doi.org/10.18502/fbt.v13i2.21940

Vancouver

Arabian H, Karimian A, Marateb HR, Migliorelli C, Mañanas MA, Romero S, et al. An Effective Method to Repair Poor Signal of Magnetoencephalography Channel Data. Frontiers in Biomedical Technologies. 2026. doi:10.18502/fbt.v13i2.21940

BibTeX
@article{Arabian2026,
  author = {Arabian, Hanie and Karimian, Alireza and Marateb, Hamid Reza and Migliorelli, Carolina and Mañanas, Miquel Angel and Romero, Sergio and Russi, Antonio and Nowak, Rafał},
  title = {An Effective Method to Repair Poor Signal of Magnetoencephalography Channel Data},
  journal = {Frontiers in Biomedical Technologies},
  year = {2026},
  doi = {10.18502/fbt.v13i2.21940}
}
Kostenlos starten →