Pulse Oximetry Based on Quadrature Multiplexing of the Amplitude Modulated Photoplethysmographic Signals

Jeerasuda Koseeyaporn iD, Paramote Wardkein, Ananta Sinchai, Pattana Kainan iD, Panwit Tuwanut

Sensors · 02.07.2023 · 23 (13) · 6106

DOI: 10.3390/s23136106 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 02.07.2023. Verfasst von Jeerasuda Koseeyaporn und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand. Hauptthemen laut MEDLINE: Photoplethysmography, Oximetry. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this research, a pulse oximeter based on quadrature multiplexing of AM-PPG signals is proposed. The oximeter is operated by a microcontroller and employs a simple amplitude modulation technique to mitigate noise interference during SpO2 measurement. The two AM-PPG signals (RED and IR) are quadrature multiplexed using carrier signals with equal frequencies but a 90-degree phase difference. The study focused on noise interference caused by light intensity and hand movement. The experiment was conducted under three different levels of light intensity: 200 Lux, 950 Lux, and 2200 Lux. For each light intensity level, the SpO2 level was measured under three scenarios: hand still, shadow movement over the hand, and hand shaking. A comparison between the proposed technique and the conventional method reveals that the proposed technique offers a superior performance. The relative error of the measured SpO2 level using the proposed technique was less than 3.1% overall. Based on the study, the proposed technique is less affected by noise interference caused by light intensity and hand movement compared to the conventional method. In addition, the proposed technique has an advantage over contemporary methods in terms of computational complexity. Consequently, the proposed technique can be applied to wearable devices that include SpO2 measurement functionality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotoplethysmographyOximetryOxygenMovementHand

Stichwörter der Autor:innen

amplitude modulationfrequency-division multiplexingpulse oximetrysynchronous detector

Substanzen

Oxygen

Autor:innen und Institutionen

  • School of Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
  • College of Advanced Manufacturing Innovation, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
  • School of Information Technology, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.

ORCID-Profile: Jeerasuda Koseeyaporn, Pattana Kainan

Zitieren

APA

Koseeyaporn, J., Wardkein, P., Sinchai, A., Kainan, P., & Tuwanut, P. (2023). Pulse Oximetry Based on Quadrature Multiplexing of the Amplitude Modulated Photoplethysmographic Signals. Sensors, 23(13), 6106. https://doi.org/10.3390/s23136106

Vancouver

Koseeyaporn J, Wardkein P, Sinchai A, Kainan P, Tuwanut P. Pulse Oximetry Based on Quadrature Multiplexing of the Amplitude Modulated Photoplethysmographic Signals. Sensors. 2023;23(13):6106. doi:10.3390/s23136106

BibTeX
@article{Koseeyaporn2023,
  author = {Koseeyaporn, Jeerasuda and Wardkein, Paramote and Sinchai, Ananta and Kainan, Pattana and Tuwanut, Panwit},
  title = {Pulse Oximetry Based on Quadrature Multiplexing of the Amplitude Modulated Photoplethysmographic Signals},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {13},
  pages = {6106},
  doi = {10.3390/s23136106}
}
Kostenlos starten →