Reflection-Boosted Wearable Ring-Type Pulse Oximeters for SpO2 Measurement with High Sensitivity and Low Power Consumption
Biosensors · 2023
DOI: 10.3390/bios13070711 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von Min Gyu Joo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea. Hauptthemen laut MEDLINE: Oximetry, Wearable Electronic Devices. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Ministry of Science and ICT, Korea, MSIT (Ministry of Science and ICT), Korea.
Abstract (Originalsprache)
In this study, we demonstrated a Monte Carlo simulation to model a finger structure and to calculate the intensity of photons passing through tissues, in order to determine optimal angular separation between a photodetector (PD) and a light-emitting diode (LED), to detect SpO2. Furthermore, our model was used to suggest a mirror-coated ring-type pulse oximeter to improve the sensitivity by up to 80% and improve power consumption by up to 65% compared to the mirror-uncoated structure. A ring-type pulse oximeter (RPO) is widely used to detect photoplethysmography (PPG) signals for SpO2 measurement during sleep and health-status monitoring. Device sensitivity and the power consumption of an RPO, which are key performance indicators, vary greatly with the geometrical arrangement of PD and LED within the inner surface of an RPO. We propose a reflection-boosted design of an RPO to achieve both high sensitivity and low power consumption, and determine an optimal configuration of a PD and LED by performing a 3D Monte Carlo simulation and confirming its agreement with experimental measurement. In order to confirm the reflection-boosted performance in terms of signal-to-noise ratio, R ratio, and perfusion index (PI), RPOs were fabricated with and without a highly reflective coating, and then used for SpO2 measurement from eight participants. Our simulation allows the numerical calculation of the intensity of photon passing and scattering through finger tissues. The reflection-boosted RPO enables reliable measurement with high sensitivity, resulting in less power consumption for the LED and longer device usage than conventional RPOs without any reflective coating, in order to maintain the same level of SNR and PI. Compared to the non-reflective reference RPO, the reflection-boosted RPO design greatly enhanced both detected light intensity (67% in dc and 322% in ac signals at a wavelength λ1 = 660 nm, and also 81% and 375% at λ2 = 940 nm, respectively) and PI (23.3% at λ1 and 25.5% at λ2). Thus, the reflection-boosted design not only enhanced measurement reliability but also significantly improved power consumption, i.e., by requiring only 36% and 30% power to drive the LED sources with λ1 and λ2, respectively, to produce the device performance of a non-reflective RPO reference. It is expected that our proposed RPO provides long-term monitoring capability with low power consumption and an enhanced PI for SpO2 measurement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea.
- Department of Digital Media Communication Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea.
- Health H/W R&D Group, Samsung Electronics, Suwon 16677, Republic of Korea.
ORCID-Profile: Hyoung Won Baac
Förderung
- National Research Foundation of Korea
- Ministry of Science and ICT, Korea
- MSIT (Ministry of Science and ICT), Korea
Zitieren
APA
Joo, M. G., Lim, D. H., Park, K. K., Baek, J., Choi, J. M., & Baac, H. W. (2023). Reflection-Boosted Wearable Ring-Type Pulse Oximeters for SpO2 Measurement with High Sensitivity and Low Power Consumption. Biosensors. https://doi.org/10.3390/bios13070711
Vancouver
Joo MG, Lim DH, Park KK, Baek J, Choi JM, Baac HW. Reflection-Boosted Wearable Ring-Type Pulse Oximeters for SpO2 Measurement with High Sensitivity and Low Power Consumption. Biosensors. 2023. doi:10.3390/bios13070711
BibTeX
@article{Joo2023,
author = {Joo, Min Gyu and Lim, Dae Hyeong and Park, Kyu-Kwan and Baek, Jiwon and Choi, Jong Min and Baac, Hyoung Won},
title = {Reflection-Boosted Wearable Ring-Type Pulse Oximeters for SpO2 Measurement with High Sensitivity and Low Power Consumption},
journal = {Biosensors},
year = {2023},
doi = {10.3390/bios13070711}
}
EUVIMED