Counting Finger and Wrist Movements Using Only a Wrist-Worn, Inertial Measurement Unit: Toward Practical Wearable Sensing for Hand-Related Healthcare Applications
Sensors · 2023
DOI: 10.3390/s23125690 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Shusuke Okita und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Aerospace Engineering, University of California Irvine, Irvine, CA 92697, USA. Hauptthemen laut MEDLINE: Stroke, Wearable Electronic Devices. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Institute of Disability and Rehabilitation Research Rehabilitation Engineering Research Center on Rehabilitation Robotics, National Institutes of…, National Institute of Disability and Rehabilitation Research Rehabilitation Engineering Research Center on Rehabilitation Robotics, National Institutes of Health.
Abstract (Originalsprache)
The ability to count finger and wrist movements throughout the day with a nonobtrusive, wearable sensor could be useful for hand-related healthcare applications, including rehabilitation after a stroke, carpal tunnel syndrome, or hand surgery. Previous approaches have required the user to wear a ring with an embedded magnet or inertial measurement unit (IMU). Here, we demonstrate that it is possible to identify the occurrence of finger and wrist flexion/extension movements based on vibrations detected by a wrist-worn IMU. We developed an approach we call “Hand Activity Recognition through using a Convolutional neural network with Spectrograms” (HARCS) that trains a CNN based on the velocity/acceleration spectrograms that finger/wrist movements create. We validated HARCS with the wrist-worn IMU recordings obtained from twenty stroke survivors during their daily life, where the occurrence of finger/wrist movements was labeled using a previously validated algorithm called HAND using magnetic sensing. The daily number of finger/wrist movements identified by HARCS had a strong positive correlation to the daily number identified by HAND (R2 = 0.76, p < 0.001). HARCS was also 75% accurate when we labeled the finger/wrist movements performed by unimpaired participants using optical motion capture. Overall, the ringless sensing of finger/wrist movement occurrence is feasible, although real-world applications may require further accuracy improvements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical and Aerospace Engineering, University of California Irvine, Irvine, CA 92697, USA.
- Department of Anatomy and Neurobiology, University of California Irvine, Irvine, CA 92697, USA.
- College of Computing, Georgia Institute of Technology, Atlanta, GA 30332, USA.
- Department of Electrical Engineering and Computer Science, University of California Berkeley, Berkeley, CA 94720, USA.
- Department of Biomedical Engineering, University of California Irvine, Irvine, CA 92697, USA.
- AE Studio, Venice, CA 90291, USA.
ORCID-Profile: Shusuke Okita, David J Reinkensmeyer
Förderung
- the National Institute of Disability and Rehabilitation Research Rehabilitation Engineering Research Center on Rehabilitation Robotics, National Institutes of…
- National Institute of Disability and Rehabilitation Research Rehabilitation Engineering Research Center on Rehabilitation Robotics
- National Institutes of Health
Zitieren
APA
Okita, S., Yakunin, R., Korrapati, J., Ibrahim, M., Schwerz de Lucena, D., Chan, V., & Reinkensmeyer, D. J. (2023). Counting Finger and Wrist Movements Using Only a Wrist-Worn, Inertial Measurement Unit: Toward Practical Wearable Sensing for Hand-Related Healthcare Applications. Sensors. https://doi.org/10.3390/s23125690
Vancouver
Okita S, Yakunin R, Korrapati J, Ibrahim M, Schwerz de Lucena D, Chan V, et al. Counting Finger and Wrist Movements Using Only a Wrist-Worn, Inertial Measurement Unit: Toward Practical Wearable Sensing for Hand-Related Healthcare Applications. Sensors. 2023. doi:10.3390/s23125690
BibTeX
@article{Okita2023,
author = {Okita, Shusuke and Yakunin, Roman and Korrapati, Jathin and Ibrahim, Mina and Schwerz de Lucena, Diogo and Chan, Vicky and Reinkensmeyer, David J},
title = {Counting Finger and Wrist Movements Using Only a Wrist-Worn, Inertial Measurement Unit: Toward Practical Wearable Sensing for Hand-Related Healthcare Applications},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23125690}
}
EUVIMED