EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Spatially Resolved Protein Binding Kinetics Analysis in Microfluidic Photonic Crystal Sensors

Stefanie Lehmann iD, Fabio Aldo Kraft iD, Martina Gerken iD

Sensors · 2023

DOI: 10.3390/s23125637 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Stefanie Lehmann und 2 weiteren Autor:innen. Beteiligte Einrichtung: Integrated Systems and Photonics, Faculty of Engineering, Kiel University, 24118 Kiel, Germany. Hauptthemen laut MEDLINE: Biosensing Techniques, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, DFG within the funding program Open Access Publikationskosten.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Organ-on-a-Chip systems are emerging as an important in vitro analysis method for drug screening and medical research. For continuous biomolecular monitoring of the cell culture response, label-free detection within the microfluidic system or in the drainage tube is promising. We study photonic crystal slabs integrated with a microfluidic chip as an optical transducer for label-free biomarker detection with a non-contact readout of binding kinetics. This work analyzes the capability of same-channel reference for protein binding measurements by using a spectrometer and 1D spatially resolved data evaluation with a spatial resolution of 1.2 μm. A cross-correlation-based data-analysis procedure is implemented. First, an ethanol–water dilution series is used to obtain the limit of detection (LOD). The median of all row LODs is (2.3±0.4)×10−4 RIU with 10 s exposure time per image and (1.3±0.24)×10−4 RIU with 30 s exposure time. Next, we used a streptavidin–biotin binding process as a test system for binding kinetics. Time series of optical spectra were recorded while constantly injecting streptavidin in DPBS at concentrations of 1.6 nM, 3.3 nM, 16.6 nM and 33.3 nM into one channel half as well as the whole channel. The results show that localized binding within a microfluidic channel is achieved under laminar flow. Furthermore, binding kinetics are fading out at the microfluidic channel edge due to the velocity profile.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesMicrofluidic Analytical TechniquesMicrofluidicsProtein BindingStreptavidinKineticsOptics and Photonics

Stichwörter der Autor:innen

diffusionin-channel referencinglab-on-a-chiplabel-free biosensormicrofluidicsorgan-on-a-chipphotonic crystal biosensorprotein binding kineticsspatially resolved spectral analysis

Substanzen

Streptavidin

Autor:innen und Institutionen

  • Integrated Systems and Photonics, Faculty of Engineering, Kiel University, 24118 Kiel, Germany.

ORCID-Profile: Stefanie Lehmann, Fabio Aldo Kraft, Martina Gerken

Förderung

  • Deutsche Forschungsgemeinschaft
  • DFG within the funding program Open Access Publikationskosten

Zitieren

APA

Lehmann, S., Kraft, F. A., & Gerken, M. (2023). Spatially Resolved Protein Binding Kinetics Analysis in Microfluidic Photonic Crystal Sensors. Sensors. https://doi.org/10.3390/s23125637

Vancouver

Lehmann S, Kraft FA, Gerken M. Spatially Resolved Protein Binding Kinetics Analysis in Microfluidic Photonic Crystal Sensors. Sensors. 2023. doi:10.3390/s23125637

BibTeX
@article{Lehmann2023,
  author = {Lehmann, Stefanie and Kraft, Fabio Aldo and Gerken, Martina},
  title = {Spatially Resolved Protein Binding Kinetics Analysis in Microfluidic Photonic Crystal Sensors},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23125637}
}
Kostenlos starten →