Nanozyme-Based Colorimetric Assay on a Magnetic Microfluidic Platform for Integrated Detection of TTX
Biosensors · 2026
DOI: 10.3390/bios16020089 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Chenqi Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Xiangfu Laboratory, Jiashan 314100, China. Hauptthemen laut MEDLINE: Colorimetry, Tetrodotoxin, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Qinghai Provincial Department of Science and Technology Key Research and Development and Transformation Program, National Key Research and Development Program of China, Equipment research and development projects of the Chinese Academy of Sciences.
Abstract (Originalsprache)
Tetrodotoxin (TTX) is a potent marine neurotoxin, necessitating sensitive and user-friendly on-site assays. To address long workflows of traditional immunoassays and limited signal amplification in colorimetric microfluidics, we developed a nanozyme-catalyzed colorimetric magnetic microfluidic immunosensor (Nano-CMI). This platform combines an aptamer–antibody sandwich capture format with catalytic amplification via AuNR@Pt@m-SiO2 (APMS) nanozymes on a magnetically actuated microfluidic chip. Magnetic actuation simplifies sample handling and washing, while APMS catalysis enhances sensitivity and visual readout. The Nano-CMI has been used for the detection of TTX samples ranging from 0.2 to 20 ng/mL with a detection limit of 0.2 ng/mL in 10 min, following the linear equation: y = −31.14ln x + 110.15, and the entire “capture-reaction-detection” workflow can be completed within 1 h. With rapid response, minimal hands-on time, and robust performance, this platform offers a practical, high-sensitivity solution for on-site TTX screening in food safety and customs inspection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Xiangfu Laboratory, Jiashan 314100, China.
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China.
- School of Microelectronics, Shanghai University, Shanghai 201800, China.
- Institute of Medical Chip, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China.
- Shanghai Frontier Innovation Research Institute, Shanghai 201108, China.
ORCID-Profile: Chenqi Zhang, Chang Chen, Shilun Feng
Förderung
- Qinghai Provincial Department of Science and Technology Key Research and Development and Transformation Program
- National Key Research and Development Program of China
- Equipment research and development projects of the Chinese Academy of Sciences
- the Science and Technology Commission of Shanghai Municipality Project
- Xiangfu Lab Research Project
- Science and Technology Commission of Shanghai Municipality Project
Zitieren
APA
Zhang, C., Wu, S., Zhang, F., Chen, C., Zhao, J., Feng, S., & Liu, B. (2026). Nanozyme-Based Colorimetric Assay on a Magnetic Microfluidic Platform for Integrated Detection of TTX. Biosensors. https://doi.org/10.3390/bios16020089
Vancouver
Zhang C, Wu S, Zhang F, Chen C, Zhao J, Feng S, et al. Nanozyme-Based Colorimetric Assay on a Magnetic Microfluidic Platform for Integrated Detection of TTX. Biosensors. 2026. doi:10.3390/bios16020089
BibTeX
@article{Zhang2026,
author = {Zhang, Chenqi and Wu, Shuo and Zhang, Fangzhou and Chen, Chang and Zhao, Jianlong and Feng, Shilun and Liu, Bo},
title = {Nanozyme-Based Colorimetric Assay on a Magnetic Microfluidic Platform for Integrated Detection of TTX},
journal = {Biosensors},
year = {2026},
doi = {10.3390/bios16020089}
}
EUVIMED