Motion Artifacts Reduction for Noninvasive Hemodynamic Monitoring of Conscious Patients Using Electrical Impedance Tomography: A Preliminary Study
Sensors · 2023
DOI: 10.3390/s23115308 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Thi Hang Dang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Engineering, Graduate School, Kyung Hee University, Seoul 02453, Republic of Korea. Hauptthemen laut MEDLINE: Artifacts, Hemodynamic Monitoring. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Korea Medical Device Development Fund, Ministry of Trade, Industry and Energy.
Abstract (Originalsprache)
Electrical impedance tomography (EIT) can monitor the real-time hemodynamic state of a conscious and spontaneously breathing patient noninvasively. However, cardiac volume signal (CVS) extracted from EIT images has a small amplitude and is sensitive to motion artifacts (MAs). This study aimed to develop a new algorithm to reduce MAs from the CVS for more accurate heart rate (HR) and cardiac output (CO) monitoring in patients undergoing hemodialysis based on the source consistency between the electrocardiogram (ECG) and the CVS of heartbeats. Two signals were measured at different locations on the body through independent instruments and electrodes, but the frequency and phase were matched when no MAs occurred. A total of 36 measurements with 113 one-hour sub-datasets were collected from 14 patients. As the number of motions per hour (MI) increased over 30, the proposed algorithm had a correlation of 0.83 and a precision of 1.65 beats per minute (BPM) compared to the conventional statical algorithm of a correlation of 0.56 and a precision of 4.04 BPM. For CO monitoring, the precision and upper limit of the mean ∆CO were 3.41 and 2.82 L per minute (LPM), respectively, compared to 4.05 and 3.82 LPM for the statistical algorithm. The developed algorithm could reduce MAs and improve HR/CO monitoring accuracy and reliability by at least two times, particularly in high-motion environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Engineering, Graduate School, Kyung Hee University, Seoul 02453, Republic of Korea.
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Bundang Hospital, Seongnam-si 13620, Republic of Korea.
- Medical Science Research Institute, Kyung Hee University Medical Center, Seoul 02447, Republic of Korea.
- Department of Biomedical Engineering, School of Medicine, Kyung Hee University, Seoul 02453, Republic of Korea.
ORCID-Profile: Kyounghun Lee, Tong In Oh
Förderung
- National Research Foundation of Korea
- Korea Medical Device Development Fund
- Ministry of Trade, Industry and Energy
Zitieren
APA
Dang, T. H., Jang, G. Y., Lee, K., & Oh, T. I. (2023). Motion Artifacts Reduction for Noninvasive Hemodynamic Monitoring of Conscious Patients Using Electrical Impedance Tomography: A Preliminary Study. Sensors. https://doi.org/10.3390/s23115308
Vancouver
Dang TH, Jang GY, Lee K, Oh TI. Motion Artifacts Reduction for Noninvasive Hemodynamic Monitoring of Conscious Patients Using Electrical Impedance Tomography: A Preliminary Study. Sensors. 2023. doi:10.3390/s23115308
BibTeX
@article{Dang2023,
author = {Dang, Thi Hang and Jang, Geuk Young and Lee, Kyounghun and Oh, Tong In},
title = {Motion Artifacts Reduction for Noninvasive Hemodynamic Monitoring of Conscious Patients Using Electrical Impedance Tomography: A Preliminary Study},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23115308}
}
EUVIMED