Effect of a Patient-Specific Structural Prior Mask on Electrical Impedance Tomography Image Reconstructions
Sensors · 2023
DOI: 10.3390/s23094551 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Rongqing Chen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Technical Medicine (ITeM), Hochschule Furtwangen, Jakob-Kienzle-Str. 17, 78054 Villingen-Schwenningen, Germany. Hauptthemen laut MEDLINE: Tomography, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry of Education and Research, European Commission, "Innovative Projects" MWK-BW.
Abstract (Originalsprache)
Electrical Impedance Tomography (EIT) is a low-cost imaging method which reconstructs two-dimensional cross-sectional images, visualising the impedance change within the thorax. However, the reconstruction of an EIT image is an ill-posed inverse problem. In addition, blurring, anatomical alignment, and reconstruction artefacts can hinder the interpretation of EIT images. In this contribution, we introduce a patient-specific structural prior mask into the EIT reconstruction process, with the aim of improving image interpretability. Such a prior mask ensures that only conductivity changes within the lung regions are reconstructed. To evaluate the influence of the introduced structural prior mask, we conducted numerical simulations with two scopes in terms of their different ventilation statuses and varying atelectasis scales. Quantitative analysis, including the reconstruction error and figures of merit, was applied in the evaluation procedure. The results show that the morphological structures of the lungs introduced by the mask are preserved in the EIT reconstructions and the reconstruction artefacts are decreased, reducing the reconstruction error by 25.9% and 17.7%, respectively, in the two EIT algorithms included in this contribution. The use of the structural prior mask conclusively improves the interpretability of the EIT images, which could facilitate better diagnosis and decision-making in clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute for Technical Medicine (ITeM), Hochschule Furtwangen, Jakob-Kienzle-Str. 17, 78054 Villingen-Schwenningen, Germany.
- Faculty of Engineering, University of Freiburg, Georges-Koehler-Allee 101, 79110 Freiburg, Germany.
ORCID-Profile: Rongqing Chen, Alberto Battistel, Knut Moeller
Förderung
- Federal Ministry of Education and Research
- European Commission
- "Innovative Projects" MWK-BW
- German Federal Ministry of Education and Research
- H2020 MSCA Rise
- AIRLobe
Zitieren
APA
Chen, R., Krueger-Ziolek, S., Battistel, A., Rupitsch, S. J., & Moeller, K. (2023). Effect of a Patient-Specific Structural Prior Mask on Electrical Impedance Tomography Image Reconstructions. Sensors. https://doi.org/10.3390/s23094551
Vancouver
Chen R, Krueger-Ziolek S, Battistel A, Rupitsch SJ, Moeller K. Effect of a Patient-Specific Structural Prior Mask on Electrical Impedance Tomography Image Reconstructions. Sensors. 2023. doi:10.3390/s23094551
BibTeX
@article{Chen2023,
author = {Chen, Rongqing and Krueger-Ziolek, Sabine and Battistel, Alberto and Rupitsch, Stefan J and Moeller, Knut},
title = {Effect of a Patient-Specific Structural Prior Mask on Electrical Impedance Tomography Image Reconstructions},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23094551}
}
EUVIMED