Contrast-Enhanced EIT Robustly Tracks Regional Lung Perfusion Compared to Non-Enhanced EIT and Pulmonary CT
IEEE Transactions on Medical Imaging · 2025-09 · 44 (9) · 3683-3693
DOI: 10.1109/tmi.2025.3552037 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2025-09. Verfasst von Diogo F Silva und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Electric Impedance, Lung, Tomography, Tomography, X-Ray Computed. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Regional perfusion monitoring, often performed by pulmonary perfusion computed tomography, is vital in intensive care units. Electrical impedance tomography, repeatable and of non-invasive nature, could provide an attractive alternative. This study compares non-enhanced and contrast-enhanced electrical impedance tomography to computed tomography under induced central to peripheral lung perfusion impairments and cardiac output modulation in 11 animals. A new algorithmic framework using multi-compartment modeling and tracer kinetics was developed to improve perfusion estimation. A multi-resolution mixed models analysis shows electrical impedance tomography agrees poorly with computed tomography in static monitoring, with limits of agreement exceeding relative errors of 100%. For trend tracking,contrast-enhancement with 5.85% NaCl yielded concordance rates above 80%, and over 90% for peripheral impairments, emerging as a robust tracker of coarse to fine perfusion changes. Non-enhanced electrical impedance tomography peaked around 60% under central impairment and cardiac modulation, proving to be less reliable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Silva, D. F., Reinartz, S., Muders, T., Wodack, K., Putensen, C., Siepmann, R., Hentze, B., & Leonhardt, S. (2025). Contrast-Enhanced EIT Robustly Tracks Regional Lung Perfusion Compared to Non-Enhanced EIT and Pulmonary CT. IEEE Transactions on Medical Imaging, 44(9), 3683-3693. https://doi.org/10.1109/tmi.2025.3552037
Vancouver
Silva DF, Reinartz S, Muders T, Wodack K, Putensen C, Siepmann R, et al. Contrast-Enhanced EIT Robustly Tracks Regional Lung Perfusion Compared to Non-Enhanced EIT and Pulmonary CT. IEEE Transactions on Medical Imaging. 2025;44(9):3683-3693. doi:10.1109/tmi.2025.3552037
BibTeX
@article{Silva2025,
author = {Silva, Diogo F and Reinartz, Sebastian and Muders, Thomas and Wodack, Karin and Putensen, Christian and Siepmann, Robert and Hentze, Benjamin and Leonhardt, Steffen},
title = {Contrast-Enhanced EIT Robustly Tracks Regional Lung Perfusion Compared to Non-Enhanced EIT and Pulmonary CT},
journal = {IEEE Transactions on Medical Imaging},
year = {2025},
volume = {44},
number = {9},
pages = {3683--3693},
doi = {10.1109/tmi.2025.3552037}
}
EUVIMED