EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Investigation on the Possible Application Areas of Low-Cost PM Sensors for Air Quality Monitoring

Domenico Suriano iD, Mario Prato

Sensors · 14.04.2023 · 23 (8) · 3976

DOI: 10.3390/s23083976 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 14.04.2023. Verfasst von Domenico Suriano und 1 weiteren Autor:innen. Beteiligte Einrichtung: ENEA-Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Department for Sustainability-Brindisi Research Cente…. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In recent years, the availability on the market of low-cost sensors (LCSs) and low-cost monitors (LCMs) for air quality monitoring has attracted the interest of scientists, communities, and professionals. Although the scientific community has raised concerns about their data quality, they are still considered a possible alternative to regulatory monitoring stations due to their cheapness, compactness, and lack of maintenance costs. Several studies have performed independent evaluations to investigate their performance, but a comparison of the results is difficult due to the different test conditions and metrics adopted. The U.S. Environmental Protection Agency (EPA) tried to provide a tool for assessing the possible uses of LCSs or LCMs by publishing guidelines to assign suitable application areas for each of them on the basis of the mean normalized bias (MNB) and coefficient of variance (CV) indicators. Until today, very few studies have analyzed LCS performance by referring to the EPA guidelines. This research aimed to understand the performance and the possible application areas of two PM sensor models (PMS5003 and SPS30) on the basis of the EPA guidelines. We computed the R2, RMSE, MAE, MNB, CV, and other performance indicators and found that the coefficient of determination (R2) ranged from 0.55 to 0.61, while the root mean squared error (RMSE) ranged from 11.02 µg/m3 to 12.09 µg/m3. Moreover, the application of a correction factor to include the humidity effect produced an improvement in the performance of the PMS5003 sensor models. We also found that, based on the MNB and CV values, the EPA guidelines assigned the SPS30 sensors to the “informal information about the presence of the pollutant” application area (Tier I), while PMS5003 sensors were assigned to the “supplemental monitoring of regulatory networks” area (Tier III). Although the usefulness of the EPA guidelines is acknowledged, it appears that improvements are necessary to increase their effectiveness.

Schlagwörter

Stichwörter der Autor:innen

EPA guidelinesPM sensorsair pollutantsair quality monitoringfield evaluationgravimetric methodlow-cost sensorssensor evaluation

Autor:innen und Institutionen

  • ENEA-Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Department for Sustainability-Brindisi Research Center, SS. 7 Appia, km 706, 72100 Brindisi, Italy.

ORCID-Profile: Domenico Suriano

Zitieren

APA

Suriano, D., & Prato, M. (2023). An Investigation on the Possible Application Areas of Low-Cost PM Sensors for Air Quality Monitoring. Sensors, 23(8), 3976. https://doi.org/10.3390/s23083976

Vancouver

Suriano D, Prato M. An Investigation on the Possible Application Areas of Low-Cost PM Sensors for Air Quality Monitoring. Sensors. 2023;23(8):3976. doi:10.3390/s23083976

BibTeX
@article{Suriano2023,
  author = {Suriano, Domenico and Prato, Mario},
  title = {An Investigation on the Possible Application Areas of Low-Cost PM Sensors for Air Quality Monitoring},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {8},
  pages = {3976},
  doi = {10.3390/s23083976}
}
Kostenlos starten →