EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Monitoring and apportioning sources of indoor air quality using low-cost particulate matter sensors

Dimitrios Bousiotis, Leah-Nani S Alconcel, David C S Beddows, Roy M Harrison, Francis D Pope

Environment International · 2023-04 · 174 · 107907

DOI: 10.1016/j.envint.2023.107907 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environment International, 2023-04. Verfasst von Dimitrios Bousiotis und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Environmental Health and Risk Management, School of Geography, Earth and Environmental Sciences, University of Birmingham, Edgbaston, Bir…. Hauptthemen laut MEDLINE: Air Pollution, Indoor, Air Pollutants, Air Pollution. Die Arbeit wurde bisher 76-mal zitiert (Crossref) und nennt 91 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Environment Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Air quality is one of the most important factors in public health. While outdoor air quality is widely studied, the indoor environment has been less scrutinised, even though time spent indoors is typically much greater than outdoors. The emergence of low-cost sensors can help assess indoor air quality. This study provides a new methodology, utilizing low-cost sensors and source apportionment techniques, to understand the relative importance of indoor and outdoor air pollution sources upon indoor air quality. The methodology is tested with three sensors placed in different rooms inside an exemplar house (bedroom, kitchen and office) and one outdoors. When the family was present, the bedroom had the highest average concentrations for PM2.5 and PM10 (3.9 ± 6.8 ug/m3 and 9.6 ± 12.7 μg/m3 respectively), due to the activities undertaken there and the presence of softer furniture and carpeting. The kitchen, while presenting the lowest PM concentrations for both size ranges (2.8 ± 5.9 ug/m3 and 4.2 ± 6.9 μg/m3 respectively), presented the highest PM spikes, especially during cooking times. Increased ventilation in the office resulted in the highest PM1 concentration (1.6 ± 1.9 μg/m3), highlighting the strong effect of infiltration of outdoor air for the smallest particles. Source apportionment, via positive matrix factorisation (PMF), showed that up to 95 % of the PM1 was found to be of outdoor sources in all the rooms. This effect was reduced as particle size increased, with outdoor sources contributing >65 % of the PM2.5, and up to 50 % of the PM10, depending on the room studied. The new approach to elucidate the contributions of different sources to total indoor air pollution exposure, described in this paper, is easily scalable and translatable to different indoor locations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Air Pollution, IndoorAir PollutantsAir PollutionParticulate MatterEnvironmental MonitoringParticle Size

Stichwörter der Autor:innen

ExposureIndoor air qualityInfiltrationPM2.5Particulate matterSource apportionment

Substanzen

Particulate MatterAir Pollutants

Autor:innen und Institutionen

  • Division of Environmental Health and Risk Management, School of Geography, Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom.
  • School of Metallurgy and Materials, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom.
  • Division of Environmental Health and Risk Management, School of Geography, Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom. Electronic address: f.pope@bham.ac.uk.

Förderung

  • Natural Environment Research Council

Zitieren

APA

Bousiotis, D., Alconcel, L. S., Beddows, D. C. S., Harrison, R. M., & Pope, F. D. (2023). Monitoring and apportioning sources of indoor air quality using low-cost particulate matter sensors. Environment International, 174, 107907. https://doi.org/10.1016/j.envint.2023.107907

Vancouver

Bousiotis D, Alconcel LS, Beddows DCS, Harrison RM, Pope FD. Monitoring and apportioning sources of indoor air quality using low-cost particulate matter sensors. Environment International. 2023;174:107907. doi:10.1016/j.envint.2023.107907

BibTeX
@article{Bousiotis2023,
  author = {Bousiotis, Dimitrios and Alconcel, Leah-Nani S and Beddows, David C S and Harrison, Roy M and Pope, Francis D},
  title = {Monitoring and apportioning sources of indoor air quality using low-cost particulate matter sensors},
  journal = {Environment International},
  year = {2023},
  volume = {174},
  pages = {107907},
  doi = {10.1016/j.envint.2023.107907}
}
Kostenlos starten →