Validating Force Sensitive Resistor Strip Sensors for Cardiorespiratory Measurement during Sleep: A Preliminary Study
Sensors · 2023
DOI: 10.3390/s23083973 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Mostafa Haghi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Ubiquitous Computing Laboratory, Department of Computer Science, HTWG Konstanz, 78462 Konstanz, Germany. Hauptthemen laut MEDLINE: Sleep, Respiratory Rate. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Carl Zeiss Foundation.
Abstract (Originalsprache)
Sleep disorders can impact daily life, affecting physical, emotional, and cognitive well-being. Due to the time-consuming, highly obtrusive, and expensive nature of using the standard approaches such as polysomnography, it is of great interest to develop a noninvasive and unobtrusive in-home sleep monitoring system that can reliably and accurately measure cardiorespiratory parameters while causing minimal discomfort to the user’s sleep. We developed a low-cost Out of Center Sleep Testing (OCST) system with low complexity to measure cardiorespiratory parameters. We tested and validated two force-sensitive resistor strip sensors under the bed mattress covering the thoracic and abdominal regions. Twenty subjects were recruited, including 12 males and 8 females. The ballistocardiogram signal was processed using the 4th smooth level of the discrete wavelet transform and the 2nd order of the Butterworth bandpass filter to measure the heart rate and respiration rate, respectively. We reached a total error (concerning the reference sensors) of 3.24 beats per minute and 2.32 rates for heart rate and respiration rate, respectively. For males and females, heart rate errors were 3.47 and 2.68, and respiration rate errors were 2.32 and 2.33, respectively. We developed and verified the reliability and applicability of the system. It showed a minor dependency on sleeping positions, one of the major cumbersome sleep measurements. We identified the sensor under the thoracic region as the optimal configuration for cardiorespiratory measurement. Although testing the system with healthy subjects and regular patterns of cardiorespiratory parameters showed promising results, further investigation is required with the bandwidth frequency and validation of the system with larger groups of subjects, including patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ubiquitous Computing Laboratory, Department of Computer Science, HTWG Konstanz, 78462 Konstanz, Germany.
- Computer Science Department, University of Seville, 41012 Seville, Spain.
- Internet of Things Laboratory, School of Informatics, Reutlingen University, 72762 Reutlingen, Germany.
ORCID-Profile: Mostafa Haghi, Akhmadbek Asadov, Andrei Boiko, Juan Antonio Ortega, Natividad Martínez Madrid, Ralf Seepold
Förderung
- Carl Zeiss Foundation
Zitieren
APA
Haghi, M., Asadov, A., Boiko, A., Ortega, J. A., Martínez Madrid, N., & Seepold, R. (2023). Validating Force Sensitive Resistor Strip Sensors for Cardiorespiratory Measurement during Sleep: A Preliminary Study. Sensors. https://doi.org/10.3390/s23083973
Vancouver
Haghi M, Asadov A, Boiko A, Ortega JA, Martínez Madrid N, Seepold R. Validating Force Sensitive Resistor Strip Sensors for Cardiorespiratory Measurement during Sleep: A Preliminary Study. Sensors. 2023. doi:10.3390/s23083973
BibTeX
@article{Haghi2023,
author = {Haghi, Mostafa and Asadov, Akhmadbek and Boiko, Andrei and Ortega, Juan Antonio and Martínez Madrid, Natividad and Seepold, Ralf},
title = {Validating Force Sensitive Resistor Strip Sensors for Cardiorespiratory Measurement during Sleep: A Preliminary Study},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23083973}
}
EUVIMED