Aluminum Thin Film Nanostructure Traces in Pediatric EEG Net for MRI and CT Artifact Reduction
Sensors · 2023
DOI: 10.3390/s23073633 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Hongbae Jeong und 8 weiteren Autor:innen. Beteiligte Einrichtung: AA. Martinos Center, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA 02129, USA. Hauptthemen laut MEDLINE: Artifacts, Aluminum. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NICHD NIH HHS, NIBIB NIH HHS, NIH HHS.
Abstract (Originalsprache)
Magnetic resonance imaging (MRI) and continuous electroencephalogram (EEG) monitoring are essential in the clinical management of neonatal seizures. EEG electrodes, however, can significantly degrade the image quality of both MRI and CT due to substantial metallic artifacts and distortions. Thus, we developed a novel thin film trace EEG net (“NeoNet”) for improved MRI and CT image quality without compromising the EEG signal quality. The aluminum thin film traces were fabricated with an ultra-high-aspect ratio (up to 17,000:1, with dimensions 30 nm × 50.8 cm × 100 µm), resulting in a low density for reducing CT artifacts and a low conductivity for reducing MRI artifacts. We also used numerical simulation to investigate the effects of EEG nets on the B1 transmit field distortion in 3 T MRI. Specifically, the simulations predicted a 65% and 138% B1 transmit field distortion higher for the commercially available copper-based EEG net (“CuNet”, with and without current limiting resistors, respectively) than with NeoNet. Additionally, two board-certified neuroradiologists, blinded to the presence or absence of NeoNet, compared the image quality of MRI images obtained in an adult and two children with and without the NeoNet device and found no significant difference in the degree of artifact or image distortion. Additionally, the use of NeoNet did not cause either: (i) CT scan artifacts or (ii) impact the quality of EEG recording. Finally, MRI safety testing confirmed a maximum temperature rise associated with the NeoNet device in a child head-phantom to be 0.84 °C after 30 min of high-power scanning, which is within the acceptance criteria for the temperature for 1 h of normal operating mode scanning as per the FDA guidelines. Therefore, the proposed NeoNet device has the potential to allow for concurrent EEG acquisition and MRI or CT scanning without significant image artifacts, facilitating clinical care and EEG/fMRI pediatric research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- AA. Martinos Center, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA 02129, USA.
- Department of Newborn Medicine, Fetal-Neonatal Neuroimaging and Developmental Science Center, Boston Children's Hospital, Boston, MA 02115, USA.
- Department of Pediatrics, Baystate Medical Center, University of Massachusetts Medical School, Springfield, MA 01605, USA.
- Brain Products GmbH, 82205 Gilching, Germany.
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA.
- Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.
ORCID-Profile: Hongbae Jeong, Georgios Ntolkeras, Jurriaan M Peters, Patricia Ellen Grant, Giorgio Bonmassar
Förderung
- NICHD NIH HHS
- NIBIB NIH HHS
- NIH HHS
- NIH/NIBIB
- NSF
Zitieren
APA
Jeong, H., Ntolkeras, G., Warbrick, T., Jaschke, M., Gupta, R., Lev, M. H., Peters, J. M., Grant, P. E., & Bonmassar, G. (2023). Aluminum Thin Film Nanostructure Traces in Pediatric EEG Net for MRI and CT Artifact Reduction. Sensors. https://doi.org/10.3390/s23073633
Vancouver
Jeong H, Ntolkeras G, Warbrick T, Jaschke M, Gupta R, Lev MH, et al. Aluminum Thin Film Nanostructure Traces in Pediatric EEG Net for MRI and CT Artifact Reduction. Sensors. 2023. doi:10.3390/s23073633
BibTeX
@article{Jeong2023,
author = {Jeong, Hongbae and Ntolkeras, Georgios and Warbrick, Tracy and Jaschke, Manfred and Gupta, Rajiv and Lev, Michael H and Peters, Jurriaan M and Grant, Patricia Ellen and Bonmassar, Giorgio},
title = {Aluminum Thin Film Nanostructure Traces in Pediatric EEG Net for MRI and CT Artifact Reduction},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23073633}
}
EUVIMED