EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Benchmarking of Contactless Heart Rate Measurement Systems in ARM-Based Embedded Platforms

Andrea Manni iD, Andrea Caroppo iD, Gabriele Rescio iD, Pietro Siciliano iD, Alessandro Leone iD

Sensors · 2023

DOI: 10.3390/s23073507 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Andrea Manni und 4 weiteren Autor:innen. Beteiligte Einrichtung: National Research Council of Italy, Institute for Microelectronics and Microsystems, 73100 Lecce, Italy. Hauptthemen laut MEDLINE: Benchmarking, Heart Rate Determination. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: MUR-Italian Ministry for University and Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Heart rate monitoring is especially important for aging individuals because it is associated with longevity and cardiovascular risk. Typically, this vital parameter can be measured using wearable sensors, which are widely available commercially. However, wearable sensors have some disadvantages in terms of acceptability, especially when used by elderly people. Thus, contactless solutions have increasingly attracted the scientific community in recent years. Camera-based photoplethysmography (also known as remote photoplethysmography) is an emerging method of contactless heart rate monitoring that uses a camera and a processing unit on the hardware side, and appropriate image processing methodologies on the software side. This paper describes the design and implementation of a novel pipeline for heart rate estimation using a commercial and low-cost camera as the input device. The pipeline’s performance was tested and compared on a desktop PC, a laptop, and three different ARM-based embedded platforms (Raspberry Pi 4, Odroid N2+, and Jetson Nano). The results showed that the designed and implemented pipeline achieved an average accuracy of about 96.7% for heart rate estimation, with very low variance (between 1.5% and 2.5%) across processing platforms, user distances from the camera, and frame resolutions. Furthermore, benchmark analysis showed that the Odroid N2+ platform was the most convenient in terms of CPU load, RAM usage, and average execution time of the algorithmic pipeline.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BenchmarkingHeart Rate DeterminationHumansAgedHeart RateMonitoring, PhysiologicPhotoplethysmographySignal Processing, Computer-Assisted

Stichwörter der Autor:innen

ARM-based embedded platformsbenchmark analysiscontactless monitoringheart rateremote PPG

Autor:innen und Institutionen

  • National Research Council of Italy, Institute for Microelectronics and Microsystems, 73100 Lecce, Italy.

ORCID-Profile: Andrea Manni, Andrea Caroppo, Gabriele Rescio, Pietro Siciliano, Alessandro Leone

Förderung

  • MUR-Italian Ministry for University and Research

Zitieren

APA

Manni, A., Caroppo, A., Rescio, G., Siciliano, P., & Leone, A. (2023). Benchmarking of Contactless Heart Rate Measurement Systems in ARM-Based Embedded Platforms. Sensors. https://doi.org/10.3390/s23073507

Vancouver

Manni A, Caroppo A, Rescio G, Siciliano P, Leone A. Benchmarking of Contactless Heart Rate Measurement Systems in ARM-Based Embedded Platforms. Sensors. 2023. doi:10.3390/s23073507

BibTeX
@article{Manni2023,
  author = {Manni, Andrea and Caroppo, Andrea and Rescio, Gabriele and Siciliano, Pietro and Leone, Alessandro},
  title = {Benchmarking of Contactless Heart Rate Measurement Systems in ARM-Based Embedded Platforms},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23073507}
}
Kostenlos starten →