EUVIMEDEUVIMED entdecken
Crossref

Improving heart rate monitoring in the obese with time-of-flight photoplethysmography (TOF-PPG): a quantitative analysis of source-detector-distance effect

Elizabeth Badolato, Andrew Little, V N Du Le

Optics Express · 2024

DOI: 10.1364/oe.510977 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, 2024. Verfasst von Elizabeth Badolato und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: Heart Rate Determination, Obesity, Morbid. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 47 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Commercial photoplethysmography (PPG) sensors rely on the measurement of continuous-wave diffuse reflection signals (CW-DRS) to monitor heart rate. Using Monte Carlo modeling of light propagation in skin, we quantitatively evaluate the dependence of continuous-wave photoplethysmography (CW-PPG) in commercial wearables on source-detector distance (SDD). Specifically, when SDD increases from 0.5 mm to 3.3 mm, CW-PPG signal increases by roughly 846% for non-obese (NOB) skin and roughly 683% for morbidly obese (MOB) skin. Ultimately, we introduce the concept of time-of-flight PPG (TOF-PPG) which can significantly improve heart rate signals. Our model shows that the optimized TOF-PPG improves heart rate monitoring experiences by roughly 47.9% in NOB and 93.2% in MOB when SDD = 3.3 mm is at green light. Moving forward, these results will provide a valuable source for hypothesis generation in the scientific community to improve heart rate monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Rate DeterminationObesity, MorbidHumansPhotoplethysmographyMonitoring, PhysiologicHeart RateSignal Processing, Computer-Assisted

Zitieren

APA

Badolato, E., Little, A., & Le, V. N. D. (2024). Improving heart rate monitoring in the obese with time-of-flight photoplethysmography (TOF-PPG): a quantitative analysis of source-detector-distance effect. Optics Express. https://doi.org/10.1364/oe.510977

Vancouver

Badolato E, Little A, Le VND. Improving heart rate monitoring in the obese with time-of-flight photoplethysmography (TOF-PPG): a quantitative analysis of source-detector-distance effect. Optics Express. 2024. doi:10.1364/oe.510977

BibTeX
@article{Badolato2024,
  author = {Badolato, Elizabeth and Little, Andrew and Le, V N Du},
  title = {Improving heart rate monitoring in the obese with time-of-flight photoplethysmography (TOF-PPG): a quantitative analysis of source-detector-distance effect},
  journal = {Optics Express},
  year = {2024},
  doi = {10.1364/oe.510977}
}
Kostenlos starten →